Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 2013 | Sausages And Other Prepared Meats |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0068 # 12 Y:1986 | 12 | 1986 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $2,238 | $1,800 | Implemented |
CO0068 # 11 Y:1986 | 11 | 1986 | REPAIR AND ELIMINATE STEAM LEAKS | $2,009 | $600 | Implemented |
CO0068 # 10 Y:1986 | 10 | 1986 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,616 | $2,600 | Implemented |
CO0068 # 07 Y:1986 | 07 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,985 | $300 | Implemented |
CO0068 # 05 Y:1986 | 05 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $6,055 | $14,709 | Implemented |
CO0068 # 15 Y:1986 | 15 | 1986 | INSULATE BARE EQUIPMENT | $471 | $291 | Implemented |
CO0068 # 14 Y:1986 | 14 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,370 | $1,214 | Implemented |
CO0068 # 01 Y:1986 | 01 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,856 | $700 | Implemented |
CO0067 # 03 Y:1986 | 03 | 1986 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $3,563 | $2,200 | Implemented |
CO0067 # 13 Y:1986 | 13 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $905 | $1,206 | Implemented |
CO0067 # 12 Y:1986 | 12 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $661 | $79 | Implemented |
CO0067 # 09 Y:1986 | 09 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,130 | $250 | Implemented |
CO0067 # 08 Y:1986 | 08 | 1986 | INCREASE AMOUNT OF CONDENSATE RETURNED | $150 | $80 | Implemented |
CO0067 # 05 Y:1986 | 05 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,899 | $300 | Implemented |
CO0067 # 04 Y:1986 | 04 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,266 | $828 | Implemented |
CO0060 # 10 Y:1986 | 10 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,473 | $17,000 | Implemented |
CO0060 # 09 Y:1986 | 09 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,697 | $1,000 | Implemented |
CO0060 # 07 Y:1986 | 07 | 1986 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $734 | $930 | Implemented |
CO0060 # 05 Y:1986 | 05 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $433 | $25 | Implemented |
CO0060 # 03 Y:1986 | 03 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,357 | $300 | Implemented |
CO0055 # 01 Y:1986 | 01 | 1986 | IMPROVE LUBRICATION PRACTICES | $2,355 | $0 | Implemented |
CO0055 # 07 Y:1986 | 07 | 1986 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,802 | $200 | Implemented |
CO0055 # 06 Y:1986 | 06 | 1986 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $533 | $300 | Implemented |
CO0055 # 05 Y:1986 | 05 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $417 | $150 | Implemented |
CO0055 # 03 Y:1986 | 03 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,244 | $600 | Implemented |