IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations

2,590

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0003 # 09 Y:1984 09 1984 INSTALL / REPAIR INSULATION ON STEAM LINES $1,045 $635 Implemented
CO0003 # 10 Y:1984 10 1984 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $385 $1,494 Implemented
CO0004 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,790 $1,860 Implemented
CO0004 # 02 Y:1984 02 1984 INSULATE BARE EQUIPMENT $206 $320 Implemented
CO0004 # 04 Y:1984 04 1984 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY $772 $240 Implemented
CO0004 # 05 Y:1984 05 1984 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,990 $0 Implemented
CO0004 # 08 Y:1984 08 1984 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $785 $45 Implemented
CO0001 # 01 Y:1984 01 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $864 $300 Implemented
CO0001 # 02 Y:1984 02 1984 USE MINIMUM STEAM OPERATING PRESSURE $231 $0 Implemented
CO0001 # 03 Y:1984 03 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,145 $2,500 Implemented
CO0001 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $260 $300 Implemented
CO0001 # 05 Y:1984 05 1984 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $202 $210 Implemented
CO0001 # 06 Y:1984 06 1984 INSULATE BARE EQUIPMENT $276 $210 Implemented
CO0001 # 07 Y:1984 07 1984 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $2,085 $200 Implemented
CO0001 # 08 Y:1984 08 1984 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,000 $0 Implemented