Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
208
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0158 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,794 | $3,000 | Implemented |
CO0158 # 02 Y:1989 | 02 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,930 | $3,700 | Implemented |
CO0158 # 01 Y:1989 | 01 | 1989 | INSTALL AUTOMATIC STACK DAMPER | $860 | $1,200 | Implemented |
CO0157 # 08 Y:1989 | 08 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $245 | $460 | Not Implemented |
CO0156 # 01 Y:1989 | 01 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,970 | $250 | Implemented |
CO0156 # 02 Y:1989 | 02 | 1989 | REVISE SMOKE CLEANUP FROM OPERATIONS | $1,120 | $3,500 | Not Implemented |
CO0156 # 03 Y:1989 | 03 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,480 | $1,200 | Implemented |
CO0156 # 04 Y:1989 | 04 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $4,640 | $1,500 | Implemented |
CO0156 # 05 Y:1989 | 05 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,240 | $800 | Implemented |
CO0156 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $277 | $105 | Implemented |
CO0156 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $635 | $2,480 | Implemented |
CO0156 # 08 Y:1989 | 08 | 1989 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,470 | $1,800 | Not Implemented |
CO0156 # 09 Y:1989 | 09 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,131 | $5,000 | Not Implemented |
CO0157 # 01 Y:1989 | 01 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,518 | $250 | Implemented |
CO0157 # 09 Y:1989 | 09 | 1989 | INSULATE BARE EQUIPMENT | $320 | $200 | Not Implemented |
CO0157 # 07 Y:1989 | 07 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $290 | $300 | Implemented |
CO0157 # 06 Y:1989 | 06 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $400 | $650 | Implemented |
CO0157 # 05 Y:1989 | 05 | 1989 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,940 | $4,000 | Implemented |
CO0157 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,018 | $983 | Implemented |
CO0157 # 04 Y:1989 | 04 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $282 | $767 | Implemented |
CO0156 # 10 Y:1989 | 10 | 1989 | INSULATE BARE EQUIPMENT | $660 | $500 | Not Implemented |
CO0157 # 02 Y:1989 | 02 | 1989 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,235 | $800 | Implemented |
CO0155 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $259 | $83 | Implemented |
CO0155 # 06 Y:1989 | 06 | 1989 | COVER OPEN TANKS | $505 | $220 | Not Implemented |
CO0155 # 04 Y:1989 | 04 | 1989 | INSTALL AUTOMATIC STACK DAMPER | $990 | $500 | Implemented |