Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
66
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0143 # 06 Y:1989 | 06 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $2,142 | $3,000 | Implemented |
MA0143 # 07 Y:1989 | 07 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $19,116 | $25,000 | Not Implemented |
MA0142 # 03 Y:1989 | 03 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $42,075 | $45,870 | Not Implemented |
MA0142 # 01 Y:1989 | 01 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $16,859 | $570 | Implemented |
MA0142 # 02 Y:1989 | 02 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $39,982 | $5,700 | Not Implemented |
MA0142 # 04 Y:1989 | 04 | 1989 | INSTALL SET-BACK TIMERS | $6,809 | $900 | Not Implemented |
MA0142 # 05 Y:1989 | 05 | 1989 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $43,200 | $381,000 | Not Implemented |
MA0142 # 06 Y:1989 | 06 | 1989 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $27,100 | $13,000 | Implemented |
MA0142 # 07 Y:1989 | 07 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $52,700 | $680 | Implemented |
MA0141 # 01 Y:1989 | 01 | 1989 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $13,473 | $65,600 | Implemented |
MA0141 # 07 Y:1989 | 07 | 1989 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $1,906 | $0 | Implemented |
MA0141 # 06 Y:1989 | 06 | 1989 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $961 | $3,000 | Not Implemented |
MA0141 # 05 Y:1989 | 05 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $950 | $2,200 | Not Implemented |
MA0141 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $716 | $200 | Implemented |
MA0141 # 03 Y:1989 | 03 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,062 | $700 | Implemented |
MA0141 # 02 Y:1989 | 02 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $6,357 | $9,450 | Implemented |