Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

184

matching recommendations
Reset
SIC 373 Ship And Boat Building And Repairing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0405 # 04 Y:2007 04 2007 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $8,668 $0 Implemented
UF0405 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $19,530 $1,396 Implemented
UF0405 # 06 Y:2007 06 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $19,272 $0 Implemented
UF0405 # 07 Y:2007 07 2007 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $49,615 $42,263 Not Implemented
UF0405 # 08 Y:2007 08 2007 INSTALL TIMERS AND/OR THERMOSTATS $3,895 $542 Implemented
UF0405 # 09 Y:2007 09 2007 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $1,037 $12 Implemented
UF0405 # 10 Y:2007 10 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $44,942 $29,100 Not Implemented
UF0405 # 11 Y:2007 11 2007 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $33,577 $25,436 Not Implemented
UF0405 # 12 Y:2007 12 2007 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $595 $3,486 Not Implemented
UF0405 # 13 Y:2007 13 2007 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $3,175 $8,000 Not Implemented
MI0089 # 01 Y:2004 01 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $13,096 $600 Not Implemented
MI0089 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $22,325 $2,300 Implemented
MI0089 # 03 Y:2004 03 2004 CHECK FOR ACCURACY OF UTILITY / POWER METERS $15,302 $270 Not Implemented
MI0089 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,010 $590 Implemented
MI0089 # 05 Y:2004 05 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $25,036 $50 Implemented
MI0089 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,772 $25,286 Implemented
MI0089 # 07 Y:2004 07 2004 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,783 $4,328 Not Implemented
UF0330 # 01 Y:2003 01 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,935 $0 Not Implemented
UF0330 # 02 Y:2003 02 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,321 $0 Not Implemented
UF0330 # 03 Y:2003 03 2003 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING $1,174 $0 Implemented
UF0330 # 04 Y:2003 04 2003 $4,992 $974 Not Implemented
UF0330 # 05 Y:2003 05 2003 $43,330 $23,017 Not Implemented
UF0330 # 06 Y:2003 06 2003 $132,990 $300,000 Not Implemented
UF0245 # 01 Y:2000 01 2000 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $3,623 $50 n/a
UF0245 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $203 $360 n/a