Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

114

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0071 # 06 Y:1989 06 1989 TURN OFF EQUIPMENT WHEN NOT IN USE $1,114 $0 Not Implemented
WI0072 # 10 Y:1989 10 1989 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $730 $0 Not Implemented
WI0068 # 06 Y:1989 06 1989 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,052 $0 Not Implemented
WI0071 # 04 Y:1989 04 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $580 $1,542 Not Implemented
WI0071 # 03 Y:1989 03 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,686 $2,400 Not Implemented
WI0068 # 05 Y:1989 05 1989 IMPROVE LUBRICATION PRACTICES $1,174 $0 Not Implemented
WI0070 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $27,544 $28,341 Implemented
WI0070 # 04 Y:1989 04 1989 INSTALL TIMERS AND/OR THERMOSTATS $3,122 $250 Not Implemented
WI0071 # 02 Y:1989 02 1989 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,737 $0 Not Implemented
WI0070 # 05 Y:1989 05 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,255 $1,000 Not Implemented
WI0068 # 04 Y:1989 04 1989 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $1,353 $0 Implemented
WI0068 # 02 Y:1989 02 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,780 $5,000 Implemented
WI0068 # 03 Y:1989 03 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,616 $7,000 Not Implemented
WI0070 # 02 Y:1989 02 1989 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $16,961 $0 Implemented
WI0071 # 07 Y:1989 07 1989 INSTALL SET-BACK TIMERS $410 $200 Not Implemented
WI0068 # 01 Y:1989 01 1989 INSTALL TIMERS AND/OR THERMOSTATS $5,126 $1,300 Not Implemented
WI0071 # 01 Y:1989 01 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,005 $5,000 Not Implemented
WI0069 # 04 Y:1989 04 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $147 $0 Implemented
WI0069 # 03 Y:1989 03 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $146 $64 Not Implemented
WI0069 # 02 Y:1989 02 1989 INSTALL TIMERS AND/OR THERMOSTATS $2,584 $750 Not Implemented
WI0068 # 07 Y:1989 07 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $600 $1,000 Implemented
WI0070 # 06 Y:1989 06 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $409 $0 Implemented
WI0069 # 01 Y:1989 01 1989 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $5,954 $0 Not Implemented
WI0070 # 03 Y:1989 03 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,871 $2,400 Not Implemented
WI0071 # 05 Y:1989 05 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,333 $500 Not Implemented