Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

304

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0199 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,320 $1,800 Not Implemented
WI0199 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $1,834 $825 Not Implemented
WI0199 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $817 $1,276 Implemented
WI0199 # 04 Y:1994 04 1994 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,819 $15,000 Not Implemented
WI0199 # 05 Y:1994 05 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,504 $600 Not Implemented
WI0199 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $725 $640 Implemented
WI0199 # 07 Y:1994 07 1994 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $726 $1,000 Implemented
WI0199 # 08 Y:1994 08 1994 INSULATE BARE EQUIPMENT $342 $77 Implemented
WI0198 # 01 Y:1994 01 1994 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $10,895 $20,000 Not Implemented
WI0198 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,761 $8,956 Implemented
WI0198 # 03 Y:1994 03 1994 INSTALL OCCUPANCY SENSORS $290 $150 Not Implemented
WI0198 # 04 Y:1994 04 1994 USE PHOTOCELL CONTROLS $116 $75 Not Implemented
WI0198 # 05 Y:1994 05 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $8,734 $21,885 Not Implemented
WI0198 # 06 Y:1994 06 1994 INSULATE BARE EQUIPMENT $258 $912 Not Implemented
WI0198 # 07 Y:1994 07 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,426 $2,920 Not Implemented
WI0198 # 08 Y:1994 08 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,316 $2,257 Not Implemented
WI0198 # 09 Y:1994 09 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $687 $0 Not Implemented
WI0196 # 01 Y:1994 01 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,341 $4,404 Not Implemented
WI0196 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,005 $3,657 Implemented
WI0196 # 03 Y:1994 03 1994 USE PHOTOCELL CONTROLS $1,159 $675 Implemented
WI0196 # 04 Y:1994 04 1994 INSTALL OCCUPANCY SENSORS $626 $225 Implemented
WI0196 # 05 Y:1994 05 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,512 $500 Implemented
WI0196 # 06 Y:1994 06 1994 RECOVER WASTE HEAT FROM EQUIPMENT $303 $500 Not Implemented
WI0196 # 07 Y:1994 07 1994 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $490 $150 Not Implemented
WI0196 # 08 Y:1994 08 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $245 $1,400 Not Implemented