IAC logo
IAC Assessment: WI0199
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0199
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1994
Principal Product Laser m/c and marking of glass
NAICS n/a
SIC 3599 - Industrial Machinery, Nec
Sales $5,000,000-$10,000,000
# of Employees 85
Plant Area (Sq.Ft.) 30,000
Annual Production 0 Units
Production Hrs. Annual 6,000
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $106,706 1,483,587 kWh $0.07
Natural Gas $4,634 818 MMBtu $5.67
TOTAL ENERGY COSTS $111,340
RECOMMENDED SAVINGS* $21,087 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,610
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$11,320
Cost:
$1,800
$11,320 157,386 - - $11,320
157,386
kWh
-
-
MMBtu
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,834
Cost:
$825
$1,834 25,498 - - $1,834
25,498
kWh
-
-
MMBtu
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$817
Cost:
$1,276
$817 17,292 - - $817
17,292
kWh
-
-
MMBtu
04: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$3,819
Cost:
$15,000
$3,819 - - - $3,819
-
kWh
-
-
MMBtu
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,504
Cost:
$600
- - $1,504 266 -
-
kWh
$1,504
266
MMBtu
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$725
Cost:
$640
$725 9,965 - - $725
9,965
kWh
-
-
MMBtu
07: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$726
Cost:
$1,000
- - $726 128 -
-
kWh
$726
128
MMBtu
08: 2.2511 INSULATE BARE EQUIPMENT Savings:
$342
Cost:
$77
$342 4,689 - - $342
4,689
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$21,087
Cost:
$21,218
$18,857 214,830 $2,230 394 $18,857
214,830
kWh
$2,230
394
MMBtu
TOTAL IMPLEMENTED Savings:
$2,610
Cost:
$2,993
$1,884 31,946 $726 128 $1,884
31,946
kWh
$726
128
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas