Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
44
matching recommendationsSIC | 30 | Rubber And Miscellaneous Plastics Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0055 # 06 Y:2015 | 06 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,460 | $1,880 | Not Implemented |
IP0055 # 07 Y:2015 | 07 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $568 | $1,146 | Not Implemented |
IP0055 # 04 Y:2015 | 04 | 2015 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,413 | $3 | Not Implemented |
IP0055 # 05 Y:2015 | 05 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,177 | $86 | Implemented |
IP0055 # 03 Y:2015 | 03 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,460 | $3 | Implemented |
IP0055 # 01 Y:2015 | 01 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,465 | $3 | Not Implemented |
IP0055 # 02 Y:2015 | 02 | 2015 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,351 | $0 | Implemented |
IP0042 # 03 Y:2015 | 03 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,617 | $636 | Implemented |
IP0042 # 07 Y:2015 | 07 | 2015 | CLEAN EQUIPMENT IMMEDIATELY AFTER USE | $96 | $195 | Implemented |
IP0042 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,917 | $38 | Implemented |
IP0042 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $485 | $1,183 | Implemented |
IP0042 # 01 Y:2015 | 01 | 2015 | USE OPTIMUM TEMPERATURE | $2,079 | $0 | Implemented |
IP0042 # 04 Y:2015 | 04 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,392 | $6,312 | Not Implemented |
IP0042 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,570 | $6,843 | Not Implemented |
IP0040 # 01 Y:2015 | 01 | 2015 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $37,208 | $0 | Not Implemented |
IP0040 # 11 Y:2015 | 11 | 2015 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,298 | $3,968 | Not Implemented |
IP0040 # 10 Y:2015 | 10 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $634 | $1,321 | Not Implemented |
IP0040 # 09 Y:2015 | 09 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $15,775 | $32,120 | Not Implemented |
IP0040 # 08 Y:2015 | 08 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,251 | $12,039 | Not Implemented |
IP0040 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $430 | $130 | Not Implemented |
IP0040 # 06 Y:2015 | 06 | 2015 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $896 | $212 | Not Implemented |
IP0040 # 05 Y:2015 | 05 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $168 | $8 | Not Implemented |
IP0040 # 04 Y:2015 | 04 | 2015 | RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE | $104,502 | $3,200 | Not Implemented |
IP0040 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,452 | $99 | Implemented |
IP0040 # 02 Y:2015 | 02 | 2015 | APPLY FOR INVESTMENT INCENTIVES | $1,728 | $0 | Implemented |