IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

452

matching recommendations
Reset
SIC 37 Transportation Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0149 # 02 Y:1996 02 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $190 $20 Implemented
UL0149 # 03 Y:1996 03 1996 INSTALL TIMERS AND/OR THERMOSTATS $4,888 $200 Implemented
UL0149 # 04 Y:1996 04 1996 REDUCE SCRAP PRODUCTION $16,000 $5,000 Implemented
UL0149 # 05 Y:1996 05 1996 RECOVER AND REUSE WASTE MATERIAL $4,050 $0 Not Implemented
ND0209 # 01 Y:1995 01 1995 USE RADIANT HEATER FOR SPOT HEATING $484 $0 Not Implemented
ND0209 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,079 $1,200 Implemented
ND0209 # 03 Y:1995 03 1995 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,016 $490 Implemented
ND0209 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $926 $547 Not Implemented
ND0209 # 05 Y:1995 05 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $900 $938 Not Implemented
ND0209 # 06 Y:1995 06 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,749 $7,975 Implemented
ND0209 # 07 Y:1995 07 1995 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,157 $3,720 Not Implemented
ND0209 # 08 Y:1995 08 1995 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $525 $1,400 Not Implemented
ND0209 # 09 Y:1995 09 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $151 $520 Not Implemented
ND0188 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $13,218 $10,190 Implemented
ND0188 # 02 Y:1994 02 1994 OPTIMIZE PLANT POWER FACTOR $4,736 $3,046 Implemented
ND0188 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,039 $1,365 Not Implemented
ND0188 # 04 Y:1994 04 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $494 $0 Implemented
ND0188 # 05 Y:1994 05 1994 COVER OPEN TANKS $276 $642 Not Implemented
ND0188 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $110 $320 Not Implemented
ND0188 # 07 Y:1994 07 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,241 $300 Not Implemented
ND0188 # 08 Y:1994 08 1994 USE IMMERSION HEATING IN TANKS, MELTING POTS, ETC $11,255 $26,000 Not Implemented
ND0187 # 01 Y:1994 01 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $15,561 $3,270 Implemented
ND0187 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $12,387 $15,255 Implemented
ND0187 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,902 $1,412 Not Implemented
ND0187 # 04 Y:1994 04 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $984 $0 Implemented