Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

97

matching recommendations
Reset
SIC 32 Stone, Clay, And Glass Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0440 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,744 $106 Implemented
KU0440 # 03 Y:1994 03 1994 INSTALL OCCUPANCY SENSORS $492 $550 Not Implemented
KU0440 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $63 $252 Implemented
KU0440 # 07 Y:1994 07 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,217 $1,110 Implemented
KU0440 # 08 Y:1994 08 1994 INSTALL TIMERS AND/OR THERMOSTATS $904 $600 Implemented
KU0440 # 09 Y:1994 09 1994 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $213 $220 Not Implemented
KU0440 # 04 Y:1994 04 1994 USE PHOTOCELL CONTROLS $515 $240 Implemented
KU0440 # 01 Y:1994 01 1994 INSTALL SKYLIGHTS $4,681 $14,620 Not Implemented
KU0421 # 07 Y:1994 07 1994 USE PHOTOCELL CONTROLS $199 $30 Implemented
KU0421 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,556 $19,846 Implemented
KU0421 # 01 Y:1994 01 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $8,665 $29,052 Not Implemented
KU0421 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $285 $850 Not Implemented
KU0421 # 05 Y:1994 05 1994 USE SYNTHETIC LUBRICANT $484 $366 Not Implemented
KU0421 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $996 $580 Not Implemented
KU0421 # 03 Y:1994 03 1994 SIZE AIR HANDLING GRILLS/ DUCT/S COILS TO MINIMIZE AIR RESISTANCE $1,509 $1,200 Not Implemented
KU0305 # 02 Y:1990 02 1990 REDESIGN PROCESS $27,002 $15,000 Not Implemented
KU0305 # 04 Y:1990 04 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,169 $13,750 Not Implemented
KU0305 # 05 Y:1990 05 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,945 $0 Implemented
KU0304 # 08 Y:1990 08 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $76,000 $50,000 Implemented
KU0304 # 07 Y:1990 07 1990 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $18,888 $13,080 Not Implemented
KU0304 # 06 Y:1990 06 1990 INSTALL AUTOMATIC STACK DAMPER $1,690 $3,000 Implemented
KU0305 # 01 Y:1990 01 1990 OPTIMIZE PLANT POWER FACTOR $76,107 $149,700 Implemented
KU0304 # 05 Y:1990 05 1990 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $35,795 $40,000 Not Implemented
KU0304 # 04 Y:1990 04 1990 SCHEDULE USE OF ELEVATORS TO CONSERVE ENERGY $1,365 $200 Implemented
KU0304 # 03 Y:1990 03 1990 OPTIMIZE PLANT POWER FACTOR $66,605 $54,000 Implemented