IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

399

matching recommendations
Reset
SIC 34 Fabricated Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0073 # 10 Y:1983 10 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $516 $67 Implemented
KU0078 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,695 $1,891 Not Implemented
KU0078 # 02 Y:1983 02 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,257 $167 Implemented
KU0078 # 03 Y:1983 03 1983 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $1,380 $0 Implemented
KU0078 # 04 Y:1983 04 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,470 $78 Implemented
KU0078 # 05 Y:1983 05 1983 INSTALL AUTOMATIC STACK DAMPER $1,100 $480 Implemented
KU0059 # 01 Y:1982 01 1982 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $21,854 $500 Not Implemented
KU0059 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,516 $22,000 Implemented
KU0059 # 03 Y:1982 03 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,363 $120 Implemented
KU0059 # 04 Y:1982 04 1982 INSTALL TIMERS AND/OR THERMOSTATS $1,570 $250 Not Implemented
KU0059 # 05 Y:1982 05 1982 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,405 $99 Implemented
KU0059 # 06 Y:1982 06 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $796 $139 Not Implemented
KU0035 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $54,065 $36,000 Not Implemented
KU0035 # 02 Y:1982 02 1982 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $30,995 $59,000 Not Implemented
KU0035 # 03 Y:1982 03 1982 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $24,810 $0 Not Implemented
KU0035 # 04 Y:1982 04 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,265 $535 Implemented
KU0035 # 05 Y:1982 05 1982 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $8,165 $22,000 Implemented
KU0029 # 01 Y:1981 01 1981 COVER OPEN TANKS $2,125 $55 Implemented
KU0029 # 02 Y:1981 02 1981 INSTALL TIMERS AND/OR THERMOSTATS $310 $0 Implemented
KU0029 # 03 Y:1981 03 1981 REVISE SMOKE CLEANUP FROM OPERATIONS $2,846 $3,200 Not Implemented
KU0029 # 04 Y:1981 04 1981 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,911 $0 Implemented
KU0029 # 05 Y:1981 05 1981 OPTIMIZE PLANT POWER FACTOR $310 $500 Implemented
KU0029 # 06 Y:1981 06 1981 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,568 $2,688 Implemented
KU0029 # 07 Y:1981 07 1981 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,505 $6,302 Implemented