IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,002

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0047 # 07 Y:1982 07 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,115 $1,000 Not Implemented
KU0048 # 01 Y:1982 01 1982 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $29,754 $15,000 Implemented
KU0048 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,256 $5,941 Implemented
KU0048 # 03 Y:1982 03 1982 INSULATE BARE EQUIPMENT $8,484 $21,600 Not Implemented
KU0048 # 04 Y:1982 04 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $13,580 $1,400 Implemented
KU0048 # 05 Y:1982 05 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $13,088 $13,000 Implemented
KU0048 # 06 Y:1982 06 1982 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $9,296 $1,500 Not Implemented
KU0049 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,612 $3,222 Not Implemented
KU0049 # 02 Y:1982 02 1982 USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS $42,700 $0 Not Implemented
KU0049 # 03 Y:1982 03 1982 USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY $6,750 $6,900 Not Implemented
KU0049 # 04 Y:1982 04 1982 INSTALL AUTOMATIC STACK DAMPER $399 $65 Not Implemented
KU0049 # 05 Y:1982 05 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $70 $60 Not Implemented
KU0050 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,836 $4,009 Implemented
KU0050 # 02 Y:1982 02 1982 USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS $118,344 $10,000 Implemented
KU0050 # 03 Y:1982 03 1982 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,013 $1,000 Implemented
KU0050 # 04 Y:1982 04 1982 INSTALL / REPAIR INSULATION ON STEAM LINES $11,254 $3,000 Implemented
KU0050 # 05 Y:1982 05 1982 REPAIR AND ELIMINATE STEAM LEAKS $480 $2,500 Implemented
KU0041 # 01 Y:1982 01 1982 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $12,933 $0 Not Implemented
KU0041 # 02 Y:1982 02 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,751 $7,500 Implemented
KU0041 # 03 Y:1982 03 1982 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,027 $287 Not Implemented
KU0041 # 04 Y:1982 04 1982 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $738 $1,800 Not Implemented
KU0041 # 05 Y:1982 05 1982 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,547 $0 Not Implemented
KU0041 # 06 Y:1982 06 1982 RECOVER WASTE HEAT FROM EQUIPMENT $1,134 $800 Not Implemented
KU0042 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,306 $1,000 Not Implemented
KU0042 # 02 Y:1982 02 1982 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $8,980 $0 Not Implemented