IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

342

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0096 # 02 Y:1983 02 1983 AIR CONDITION ONLY SPACE NECESSARY $1,888 $5 Not Implemented
KU0096 # 03 Y:1983 03 1983 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $999 $862 Not Implemented
KU0096 # 04 Y:1983 04 1983 TURN OFF STEAM TRACING DURING MILD WEATHER $225 $0 Not Implemented
KU0096 # 05 Y:1983 05 1983 INSTALL AUTOMATIC STACK DAMPER $420 $900 Not Implemented
KU0096 # 06 Y:1983 06 1983 ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS $266 $480 Not Implemented
KU0096 # 07 Y:1983 07 1983 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $261 $0 Not Implemented
KU0088 # 01 Y:1983 01 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $896 $450 Not Implemented
KU0088 # 02 Y:1983 02 1983 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $551 $70 Implemented
KU0088 # 03 Y:1983 03 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $309 $312 Not Implemented
KU0088 # 04 Y:1983 04 1983 INSTALL AUTOMATIC STACK DAMPER $111 $300 Not Implemented
KU0088 # 05 Y:1983 05 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $63 $60 Not Implemented
KU0089 # 01 Y:1983 01 1983 RECOVER WASTE HEAT FROM EQUIPMENT $7,499 $24,000 Implemented
KU0089 # 02 Y:1983 02 1983 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $7,163 $100 Implemented
KU0089 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $2,999 $200 Implemented
KU0089 # 04 Y:1983 04 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,058 $2,580 Implemented
KU0089 # 05 Y:1983 05 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,992 $2,970 Implemented
KU0089 # 06 Y:1983 06 1983 INCREASE AMOUNT OF CONDENSATE RETURNED $1,182 $1,044 Implemented
KU0089 # 07 Y:1983 07 1983 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $322 $550 Implemented
KU0089 # 08 Y:1983 08 1983 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $182 $0 Implemented
KU0089 # 09 Y:1983 09 1983 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $117 $170 Implemented
KU0090 # 01 Y:1983 01 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $17,326 $5,429 Not Implemented
KU0090 # 02 Y:1983 02 1983 INSTALL TIMERS AND/OR THERMOSTATS $15,389 $50,000 Not Implemented
KU0090 # 03 Y:1983 03 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,504 $5,569 Not Implemented
KU0090 # 04 Y:1983 04 1983 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $17,707 $200 Not Implemented
KU0090 # 05 Y:1983 05 1983 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $795 $152 Not Implemented