Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

74

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UL0215 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $759 $1,452 Implemented
UL0215 # 01 Y:1999 01 1999 INSTALL TIMERS AND/OR THERMOSTATS $931 $400 Not Implemented
UL0210 # 04 Y:1998 04 1998 $100,000 $200,000 Not Implemented
UL0210 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,828 $10,925 Not Implemented
UL0210 # 03 Y:1998 03 1998 REUSE / RECYCLE/ SELL PAPER PRODUCTS $22,000 $0 Implemented
UL0210 # 02 Y:1998 02 1998 OPTIMIZE PLANT POWER FACTOR $80,210 $43,420 Not Implemented
UL0185 # 06 Y:1997 06 1997 BURN WOOD BY-PRODUCTS FOR HEAT $625 $0 Not Implemented
UL0185 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $266 $7,360 Implemented
UL0185 # 03 Y:1997 03 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $677 $20 Implemented
UL0185 # 07 Y:1997 07 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $1,707 $0 Not Implemented
UL0185 # 05 Y:1997 05 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $23,580 $4,040 Not Implemented
UL0185 # 04 Y:1997 04 1997 INSTALL TIMERS AND/OR THERMOSTATS $1,320 $2,600 Not Implemented
UL0185 # 02 Y:1997 02 1997 OPTIMIZE PLANT POWER FACTOR $6,333 $6,499 Not Implemented
UL0167 # 06 Y:1996 06 1996 CONTRACT A WOOD PALLET RECYCLING COMPANY $9,000 $0 Not Implemented
UL0167 # 05 Y:1996 05 1996 INSTALL TIMERS AND/OR THERMOSTATS $1,539 $200 Not Implemented
UL0167 # 04 Y:1996 04 1996 INSTALL TIMERS AND/OR THERMOSTATS $1,860 $200 Not Implemented
UL0167 # 07 Y:1996 07 1996 USE A RAG RECYCLE SERVICE $1,500 $75 Not Implemented
UL0167 # 08 Y:1996 08 1996 RECYCLE WASTE INK AND CLEANUP SOLVENT $16,750 $25,000 Not Implemented
UL0167 # 03 Y:1996 03 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $670 $20 Not Implemented
UL0167 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $270 $1,493 Not Implemented
UL0167 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $715 $7,590 Not Implemented
UL0145 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,040 $1,151 Not Implemented
UL0145 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,159 $8,988 Not Implemented
UL0145 # 03 Y:1995 03 1995 OPTIMIZE PLANT POWER FACTOR $30,246 $21,220 Not Implemented
UL0145 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,624 $60 Not Implemented