IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

97

matching recommendations
Reset
SIC 31 Leather And Leather Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0132 # 06 Y:1994 06 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $944 $400 Implemented
ME0132 # 01 Y:1994 01 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,797 $300 Implemented
ME0132 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,931 $500 Implemented
ME0132 # 07 Y:1994 07 1994 REPAIR AND ELIMINATE STEAM LEAKS $286 $75 Implemented
ME0132 # 05 Y:1994 05 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $792 $0 Implemented
ME0125 # 06 Y:1994 06 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $990 $960 Implemented
ME0125 # 05 Y:1994 05 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $634 $500 Implemented
ME0125 # 03 Y:1994 03 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $763 $0 Implemented
ME0125 # 02 Y:1994 02 1994 RECOVER WASTE HEAT FROM EQUIPMENT $2,070 $450 Implemented
ME0125 # 01 Y:1994 01 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $416 $50 Implemented
ME0121 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,100 $400 Implemented
ME0116 # 04 Y:1993 04 1993 USE PHOTOCELL CONTROLS $2,907 $1,200 Implemented
ME0116 # 01 Y:1993 01 1993 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,946 $7,000 Implemented
ME0108 # 05 Y:1993 05 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,990 $500 Implemented
ME0108 # 04 Y:1993 04 1993 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $11,804 $18,100 Implemented
ME0108 # 03 Y:1993 03 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,170 $250 Implemented
ME0108 # 01 Y:1993 01 1993 PAY UTILITY BILLS ON TIME $5,548 $0 Implemented
ME0107 # 05 Y:1993 05 1993 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,118 $3,610 Implemented
ME0107 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,707 $931 Implemented
ME0107 # 03 Y:1993 03 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,223 $3,420 Implemented
ME0107 # 02 Y:1993 02 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,445 $2,000 Implemented
ME0107 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,132 $2,550 Implemented