Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
133
matching recommendationsNAICS | 331 | Primary Metal Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UMS004 # 02 Y:2012 | 02 | 2012 | CONVERT TO OXYFUEL BURNERS | $156,000 | $250,000 | Not Implemented |
UMS004 # 03 Y:2012 | 03 | 2012 | COVER OPEN TANKS | $41,000 | $32,000 | Not Implemented |
UMS004 # 04 Y:2012 | 04 | 2012 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $27,600 | $75,000 | Not Implemented |
UMS004 # 05 Y:2012 | 05 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,500 | $0 | Not Implemented |
UMS004 # 06 Y:2012 | 06 | 2012 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $40,000 | $40,000 | Not Implemented |
UMS004 # 07 Y:2012 | 07 | 2012 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $1,300 | $0 | Not Implemented |
UM0365 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,536 | $77,254 | Implemented |
UM0365 # 02 Y:2010 | 02 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $15,991 | $107,000 | Implemented |
UM0365 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,966 | $13,000 | Implemented |
UM0365 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $1,051 | $0 | Implemented |
UM0365 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $43,773 | $13,000 | Implemented |
UM0365 # 06 Y:2010 | 06 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,455 | $3,500 | Implemented |
UM0365 # 07 Y:2010 | 07 | 2010 | USE OPTIMUM THICKNESS INSULATION | $1,040 | $22,500 | Implemented |
UM0365 # 08 Y:2010 | 08 | 2010 | INSTALL STORM WINDOWS AND DOORS | $819 | $0 | Not Implemented |
UM0338 # 01 Y:2008 | 01 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $30,146 | $38,350 | Not Implemented |
UM0338 # 02 Y:2008 | 02 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,908 | $4,000 | Not Implemented |
UM0338 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,301 | $19,680 | Not Implemented |
UM0338 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,640 | $1,400 | Not Implemented |
UM0338 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,107 | $900 | Not Implemented |
UM0338 # 06 Y:2008 | 06 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,305 | $4,480 | Not Implemented |
UM0338 # 07 Y:2008 | 07 | 2008 | USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES | $257 | $1,095 | Not Implemented |
UM0338 # 08 Y:2008 | 08 | 2008 | INSTALL OCCUPANCY SENSORS | $103 | $270 | Not Implemented |
UM0336 # 01 Y:2008 | 01 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $31,330 | $1,650 | Implemented |
UM0336 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,116 | $200 | Implemented |
UM0336 # 03 Y:2008 | 03 | 2008 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $13,866 | $29,119 | Not Implemented |