Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
168
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0043 # 06 Y:1995 | 06 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,171 | $1,070 | Not Implemented |
MS0043 # 03 Y:1995 | 03 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $221 | $0 | Implemented |
MS0043 # 04 Y:1995 | 04 | 1995 | REDUCE VENTILATION AIR | $305 | $240 | Implemented |
MS0043 # 05 Y:1995 | 05 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,474 | $1,510 | Not Implemented |
MS0043 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,215 | $9,659 | Not Implemented |
MS0043 # 02 Y:1995 | 02 | 1995 | INSTALL OCCUPANCY SENSORS | $1,055 | $872 | Not Implemented |
MS0045 # 01 Y:1995 | 01 | 1995 | USE RADIANT HEATER FOR SPOT HEATING | $1,444 | $3,310 | Not Implemented |
MS0045 # 05 Y:1995 | 05 | 1995 | USE SYNTHETIC LUBRICANT | $225 | $20 | Not Implemented |
MS0045 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $783 | $1,219 | Not Implemented |
MS0045 # 04 Y:1995 | 04 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,512 | $440 | Not Implemented |
MS0045 # 06 Y:1995 | 06 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $96 | $100 | Not Implemented |
MS0045 # 03 Y:1995 | 03 | 1995 | COVER OPEN TANKS | $627 | $666 | Not Implemented |
MS0044 # 01 Y:1995 | 01 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,849 | $200 | n/a |
MS0044 # 02 Y:1995 | 02 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,785 | $0 | n/a |
MS0044 # 04 Y:1995 | 04 | 1995 | AIR CONDITION ONLY SPACE NECESSARY | $11,011 | $10,635 | n/a |
MS0044 # 06 Y:1995 | 06 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $989 | $760 | n/a |
MS0044 # 05 Y:1995 | 05 | 1995 | USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY | $7,392 | $7,500 | n/a |
MS0044 # 07 Y:1995 | 07 | 1995 | REDUCE VENTILATION AIR | $536 | $200 | n/a |
MS0044 # 08 Y:1995 | 08 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $234 | $202 | n/a |
MS0044 # 03 Y:1995 | 03 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $593 | $2,820 | n/a |
MS0042 # 06 Y:1995 | 06 | 1995 | USE RADIANT HEATER FOR SPOT HEATING | $7,400 | $3,132 | Implemented |
MS0042 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $64,604 | $60,000 | Implemented |
MS0042 # 02 Y:1995 | 02 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,635 | $0 | Implemented |
MS0042 # 05 Y:1995 | 05 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $13,524 | $1,400 | Implemented |
MS0042 # 04 Y:1995 | 04 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,264 | $4,785 | Implemented |