Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
188
matching recommendationsSIC | 32 | Stone, Clay, And Glass Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0280 # 01 Y:2004 | 01 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $18,958 | $500 | Not Implemented |
NC0280 # 02 Y:2004 | 02 | 2004 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $69,623 | $360,000 | Not Implemented |
NC0280 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $109,628 | $121,591 | n/a |
NC0280 # 04 Y:2004 | 04 | 2004 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $24,049 | $79,415 | n/a |
NC0280 # 05 Y:2004 | 05 | 2004 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $19,146 | $6,453 | Not Implemented |
NC0280 # 06 Y:2004 | 06 | 2004 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $4,062 | $5,600 | Not Implemented |
NC0280 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,201 | $700 | Implemented |
NC0280 # 08 Y:2004 | 08 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,341 | $2,060 | Not Implemented |
NC0280 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $745 | $686 | Not Implemented |
NC0229 # 01 Y:2002 | 01 | 2002 | LIMIT AND CONTROL SECONDARY COMBUSTION AIR IN FURNACE | $51,728 | $50,000 | Implemented |
NC0229 # 02 Y:2002 | 02 | 2002 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $55,158 | $15,000 | Implemented |
NC0229 # 03 Y:2002 | 03 | 2002 | KEEP EQUIPMENT CLEAN | $21,155 | $1,000 | Implemented |
NC0229 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $5,620 | $1,577 | Not Implemented |
NC0229 # 05 Y:2002 | 05 | 2002 | INSULATE BARE EQUIPMENT | $6,444 | $6,536 | Not Implemented |
NC0229 # 06 Y:2002 | 06 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $2,372 | $2,996 | Implemented |
NC0229 # 07 Y:2002 | 07 | 2002 | USE OPTIMUM THICKNESS INSULATION | $298 | $860 | Not Implemented |
NC0229 # 08 Y:2002 | 08 | 2002 | USE PHOTOCELL CONTROLS | $260 | $300 | Implemented |
NC0186 # 01 Y:2000 | 01 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,878 | $20 | Not Implemented |
NC0186 # 02 Y:2000 | 02 | 2000 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $3,993 | $6,400 | Not Implemented |
NC0186 # 03 Y:2000 | 03 | 2000 | USE OPTIMUM THICKNESS INSULATION | $9,327 | $32,175 | Not Implemented |
NC0186 # 04 Y:2000 | 04 | 2000 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $12,321 | $4,000 | Implemented |
NC0186 # 05 Y:2000 | 05 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,150 | $200 | Not Implemented |
NC0185 # 01 Y:2000 | 01 | 2000 | ADJUST BURNERS FOR EFFICIENT OPERATION | $637 | $800 | Implemented |
NC0185 # 02 Y:2000 | 02 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $537 | $1,700 | Not Implemented |
NC0185 # 03 Y:2000 | 03 | 2000 | DISCONNECT BALLASTS | $441 | $500 | Implemented |