IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

117

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0435 # 01 Y:1994 01 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $6,681 $1,800 Not Implemented
KU0435 # 02 Y:1994 02 1994 INSULATE BARE EQUIPMENT $2,005 $3,213 Not Implemented
KU0435 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,262 $8,110 Not Implemented
KU0435 # 04 Y:1994 04 1994 INSTALL OCCUPANCY SENSORS $996 $400 Not Implemented
KU0435 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $440 $504 Not Implemented
KU0435 # 06 Y:1994 06 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $584 $197 Not Implemented
KU0435 # 07 Y:1994 07 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $404 $120 Not Implemented
KU0434 # 01 Y:1994 01 1994 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $6,218 $300 Implemented
KU0434 # 02 Y:1994 02 1994 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $17,492 $1,000 Not Implemented
KU0434 # 03 Y:1994 03 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $7,856 $29,000 Not Implemented
KU0434 # 04 Y:1994 04 1994 RECOVER WASTE HEAT FROM EQUIPMENT $7,795 $10,100 Not Implemented
KU0434 # 05 Y:1994 05 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,951 $1,130 Implemented
KU0434 # 06 Y:1994 06 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $3,050 $825 Not Implemented
KU0434 # 07 Y:1994 07 1994 INSULATE BARE EQUIPMENT $460 $1,466 Not Implemented
KU0434 # 08 Y:1994 08 1994 USE SYNTHETIC LUBRICANT $2,090 $2,363 Not Implemented
KU0434 # 09 Y:1994 09 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $837 $1,486 Not Implemented
KU0434 # 10 Y:1994 10 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,404 $888 Implemented
KU0434 # 11 Y:1994 11 1994 INSTALL OCCUPANCY SENSORS $1,297 $2,487 Not Implemented
KU0434 # 12 Y:1994 12 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $258 $360 Implemented
KU0434 # 13 Y:1994 13 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $452 $582 Implemented
KU0433 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $21,221 $37,523 Implemented
KU0433 # 02 Y:1994 02 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $15,106 $6,315 Not Implemented
KU0433 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,113 $11,279 Implemented
KU0433 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,706 $3,160 Implemented
KU0433 # 05 Y:1994 05 1994 INSTALL OCCUPANCY SENSORS $1,461 $950 Not Implemented