Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

71

matching recommendations
Reset
SIC 30 Rubber And Miscellaneous Plastics Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0219 # 04 Y:1991 04 1991 INSTALL TIMERS AND/OR THERMOSTATS $6,693 $100 Implemented
MA0219 # 01 Y:1991 01 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $36,849 $0 Implemented
MA0219 # 02 Y:1991 02 1991 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $30,005 $7,000 Implemented
MA0219 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,604 $446 Implemented
MA0219 # 05 Y:1991 05 1991 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $8,835 $3,850 Implemented
MA0219 # 06 Y:1991 06 1991 INSTALL SET-BACK TIMERS $629 $85 Implemented
MA0159 # 06 Y:1989 06 1989 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $752 $0 Implemented
MA0159 # 04 Y:1989 04 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $444 $297 Implemented
MA0159 # 03 Y:1989 03 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $2,298 $2,700 Implemented
MA0159 # 02 Y:1989 02 1989 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $684 $3,027 Implemented
MA0135 # 07 Y:1988 07 1988 TURN OFF EQUIPMENT WHEN NOT IN USE $2,525 $0 Implemented
MA0135 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,462 $359 Implemented
MA0135 # 02 Y:1988 02 1988 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $6,147 $2,606 Implemented
MA0135 # 04 Y:1988 04 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $598 $40 Implemented
MA0135 # 05 Y:1988 05 1988 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,736 $1,140 Implemented
MA0135 # 08 Y:1988 08 1988 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $2,029 $0 Implemented
MA0121 # 01 Y:1988 01 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,877 $0 Implemented
MA0121 # 06 Y:1988 06 1988 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $7,432 $6,690 Implemented
MA0121 # 05 Y:1988 05 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,134 $187 Implemented
MA0121 # 04 Y:1988 04 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,017 $200 Implemented
MA0121 # 02 Y:1988 02 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,535 $400 Implemented