Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

59

matching recommendations
Reset
SIC 305 Hose & Belting & Gaskets & Packing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SU0248 # 13 Y:2007 13 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $89 $135 Implemented
SU0248 # 12 Y:2007 12 2007 INSTALL OCCUPANCY SENSORS $566 $823 Implemented
SU0248 # 11 Y:2007 11 2007 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $1,423 $2,030 Not Implemented
SU0248 # 10 Y:2007 10 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,967 $4,730 Not Implemented
SU0248 # 09 Y:2007 09 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,730 $1,952 Implemented
SU0248 # 07 Y:2007 07 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $38,806 $6,280 Implemented
SU0248 # 06 Y:2007 06 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,276 $515 Not Implemented
SU0248 # 05 Y:2007 05 2007 REPAIR AND ELIMINATE STEAM LEAKS $85,427 $432 Implemented
SU0248 # 04 Y:2007 04 2007 USE SYNTHETIC LUBRICANT $260 $0 Not Implemented
SU0248 # 03 Y:2007 03 2007 $546 $0 Implemented
SU0248 # 02 Y:2007 02 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,903 $0 Not Implemented
SU0248 # 01 Y:2007 01 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,292 $0 Not Implemented
SU0132 # 08 Y:2002 08 2002 RECOVER WASTE HEAT FROM EQUIPMENT $290 $107 Not Implemented
SU0132 # 01 Y:2002 01 2002 USE OPTIMUM THICKNESS INSULATION $1,746 $0 Not Implemented
SU0132 # 02 Y:2002 02 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,727 $8,057 Implemented
SU0132 # 03 Y:2002 03 2002 INSTALL TIMERS AND/OR THERMOSTATS $5,704 $472 Implemented
SU0132 # 04 Y:2002 04 2002 $5,586 $392 Implemented
SU0132 # 05 Y:2002 05 2002 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,123 $0 Implemented
SU0132 # 06 Y:2002 06 2002 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $451 $809 Not Implemented
SU0132 # 07 Y:2002 07 2002 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $357 $40 Not Implemented
SU0132 # 09 Y:2002 09 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $154 $0 Implemented
SU0132 # 10 Y:2002 10 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $48 $79 Not Implemented
MA0426 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $586 $458 Implemented
MA0426 # 05 Y:1998 05 1998 INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS $2,320 $9,100 Not Implemented
MA0426 # 04 Y:1998 04 1998 USE RADIANT HEATER FOR SPOT HEATING $902 $1,975 Not Implemented