Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
25
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0470 # 07 Y:1995 | 07 | 1995 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $3,389 | $5,720 | Not Implemented |
OK0470 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $119 | $395 | Implemented |
OK0470 # 05 Y:1995 | 05 | 1995 | INSTALL OCCUPANCY SENSORS | $225 | $224 | Implemented |
OK0470 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $309 | $40 | Implemented |
OK0470 # 03 Y:1995 | 03 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $817 | $200 | Not Implemented |
OK0470 # 02 Y:1995 | 02 | 1995 | UPGRADE OBSOLETE EQUIPMENT | $749 | $2,050 | Implemented |
OK0470 # 01 Y:1995 | 01 | 1995 | INSTALL SET-BACK TIMERS | $4,342 | $15,400 | Implemented |
OK0467 # 02 Y:1995 | 02 | 1995 | INSTALL OCCUPANCY SENSORS | $782 | $910 | Not Implemented |
OK0467 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,046 | $2,349 | Implemented |
OK0467 # 03 Y:1995 | 03 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,563 | $32,566 | Implemented |
OK0467 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,548 | $0 | Implemented |
OK0464 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $267 | $791 | Implemented |
OK0464 # 08 Y:1995 | 08 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $99 | $240 | Not Implemented |
OK0464 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $379 | $300 | Implemented |
OK0464 # 05 Y:1995 | 05 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $4,193 | $1,736 | Implemented |
OK0464 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,609 | $170 | Implemented |
OK0464 # 03 Y:1995 | 03 | 1995 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $6,347 | $6,240 | Not Implemented |
OK0464 # 02 Y:1995 | 02 | 1995 | USE PUMPS AND PIPING TO DECREASE THE FREQUENCY OF SPILLAGE DURING MATERIAL TRANSFER | $3,872 | $7,422 | Implemented |
OK0464 # 01 Y:1995 | 01 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $37,301 | $2,000 | Implemented |
OK0456 # 05 Y:1995 | 05 | 1995 | INSTALL SET-BACK TIMERS | $8,254 | $196 | Implemented |
OK0456 # 04 Y:1995 | 04 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $573 | $0 | Not Implemented |
OK0456 # 03 Y:1995 | 03 | 1995 | INSULATE BARE EQUIPMENT | $598 | $2,277 | Not Implemented |
OK0456 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,924 | $2,916 | Not Implemented |
OK0456 # 01 Y:1995 | 01 | 1995 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,279 | $960 | Implemented |
OK0456 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,531 | $27,426 | Implemented |