IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

152

matching recommendations
Reset
SIC 36 Electronic & Other Electric Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0164 # 01 Y:1985 01 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,930 $891 Implemented
OK0164 # 03 Y:1985 03 1985 USE RADIANT HEATER FOR SPOT HEATING $1,900 $2,215 Implemented
OK0164 # 04 Y:1985 04 1985 TURN OFF EQUIPMENT WHEN NOT IN USE $133 $150 Implemented
OK0164 # 05 Y:1985 05 1985 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $314 $600 Implemented
OK0147 # 01 Y:1984 01 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,160 $900 Implemented
OK0147 # 02 Y:1984 02 1984 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $509 $131 Implemented
OK0147 # 03 Y:1984 03 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,650 $6,252 Implemented
OK0147 # 05 Y:1984 05 1984 USE DEMAND CONTROLLER OR LOAD SHEDDER $6,120 $1,236 Implemented
OK0147 # 06 Y:1984 06 1984 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $566 $333 Implemented
OK0147 # 07 Y:1984 07 1984 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $2,671 $1,647 Implemented
OK0147 # 08 Y:1984 08 1984 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $2,036 $720 Implemented
OK0147 # 09 Y:1984 09 1984 INSTALL TIMERS AND/OR THERMOSTATS $492 $291 Implemented
OK0147 # 10 Y:1984 10 1984 TURN OFF EQUIPMENT WHEN NOT IN USE $6,362 $1,090 Implemented
OK0142 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $164 $268 Implemented
OK0142 # 02 Y:1984 02 1984 REDUCE VENTILATION AIR $125 $0 Implemented
OK0142 # 04 Y:1984 04 1984 INSULATE BARE EQUIPMENT $488 $58 Implemented
OK0135 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,133 $856 Implemented
OK0135 # 03 Y:1984 03 1984 RECOVER WASTE HEAT FROM EQUIPMENT $207 $198 Implemented
OK0135 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $338 $596 Implemented
OK0135 # 07 Y:1984 07 1984 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $40 $50 Implemented
OK0135 # 08 Y:1984 08 1984 AIR CONDITION ONLY SPACE NECESSARY $191 $440 Implemented
OK0048 # 03 Y:1982 03 1982 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $35 $17 Implemented
OK0020 # 01 Y:1982 01 1982 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $767 $30 Implemented
OK0020 # 02 Y:1982 02 1982 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $101 $65 Implemented
OK0020 # 03 Y:1982 03 1982 INSTALL TIMERS AND/OR THERMOSTATS $567 $790 Implemented