Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
116
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0930 # 01 Y:2015 | 01 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $137,102 | $90,000 | Not Implemented |
OK0930 # 03 Y:2015 | 03 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,131 | $0 | Implemented |
OK0930 # 02 Y:2015 | 02 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $17,351 | $10,800 | Not Implemented |
OK0928 # 04 Y:2015 | 04 | 2015 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $9,143 | $18,884 | Not Implemented |
OK0928 # 11 Y:2015 | 11 | 2015 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $35,000 | $70,000 | Implemented |
OK0928 # 13 Y:2015 | 13 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $581 | $468 | Not Implemented |
OK0928 # 03 Y:2015 | 03 | 2015 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $149 | $132 | Implemented |
OK0928 # 05 Y:2015 | 05 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $988 | $2,440 | Not Implemented |
OK0928 # 02 Y:2015 | 02 | 2015 | INSTALL SET-BACK TIMERS | $2,950 | $972 | Implemented |
OK0928 # 09 Y:2015 | 09 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,212 | $863 | Implemented |
OK0928 # 12 Y:2015 | 12 | 2015 | OPTIMIZE PLANT POWER FACTOR | $2,621 | $20,000 | Not Implemented |
OK0928 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,758 | $25,753 | Implemented |
OK0928 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,832 | $38,110 | Implemented |
OK0928 # 01 Y:2015 | 01 | 2015 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $21,773 | $7,320 | Implemented |
OK0928 # 08 Y:2015 | 08 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,204 | $5,149 | Implemented |
OK0928 # 10 Y:2015 | 10 | 2015 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $6,912 | $5,775 | Not Implemented |
OK0922 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,502 | $30,324 | Implemented |
OK0922 # 07 Y:2015 | 07 | 2015 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,660 | $720 | Implemented |
OK0922 # 05 Y:2015 | 05 | 2015 | USE RADIANT HEATER FOR SPOT HEATING | $2,132 | $6,660 | Not Implemented |
OK0922 # 09 Y:2015 | 09 | 2015 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $656 | $690 | Not Implemented |
OK0922 # 04 Y:2015 | 04 | 2015 | OPTIMIZE PLANT POWER FACTOR | $37,221 | $46,451 | Not Implemented |
OK0922 # 08 Y:2015 | 08 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,542 | $780 | Not Implemented |
OK0922 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,204 | $77,600 | Implemented |
OK0922 # 01 Y:2015 | 01 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $950 | $580 | Not Implemented |
OK0922 # 06 Y:2015 | 06 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $10,800 | $22,080 | Not Implemented |