IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

275

matching recommendations
Reset
SIC 22 Textile Mill Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0422 # 04 Y:1990 04 1990 IMPROVE LUBRICATION PRACTICES $350 $0 Implemented
GT0423 # 01 Y:1990 01 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,280 $0 Not Implemented
GT0423 # 02 Y:1990 02 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,135 $10,029 Implemented
GT0423 # 03 Y:1990 03 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $668 $500 Implemented
GT0423 # 04 Y:1990 04 1990 IMPROVE LUBRICATION PRACTICES $2,000 $0 Implemented
GT0423 # 05 Y:1990 05 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,600 $2,000 Implemented
GT0423 # 06 Y:1990 06 1990 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,500 $500 Implemented
GT0423 # 07 Y:1990 07 1990 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $2,200 $1,600 Implemented
GT0423 # 08 Y:1990 08 1990 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $3,250 $7,000 Implemented
GT0423 # 09 Y:1990 09 1990 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $15,684 $11,000 Not Implemented
GT0417 # 01 Y:1990 01 1990 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $62,710 $15,000 Implemented
GT0417 # 02 Y:1990 02 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,362 $1,268 Implemented
GT0417 # 03 Y:1990 03 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $525 $0 Implemented
GT0417 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $389 $295 Implemented
GT0417 # 05 Y:1990 05 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $90,960 $210,570 Implemented
GT0417 # 06 Y:1990 06 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,970 $450 Implemented
GT0417 # 07 Y:1990 07 1990 INSTALL SET-BACK TIMERS $512 $1,800 Not Implemented
TN0379 # 01 Y:1989 01 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $23,137 $2,100 Not Implemented
TN0379 # 02 Y:1989 02 1989 KEEP LAMPS AND REFLECTORS CLEAN $20,544 $37,163 Not Implemented
TN0379 # 03 Y:1989 03 1989 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $2,703 $0 Not Implemented
TN0379 # 04 Y:1989 04 1989 USE MINIMUM STEAM OPERATING PRESSURE $1,190 $0 Not Implemented
TN0379 # 05 Y:1989 05 1989 REPAIR AND ELIMINATE STEAM LEAKS $452 $330 Not Implemented
TN0379 # 06 Y:1989 06 1989 INSULATE BARE EQUIPMENT $483 $757 Not Implemented
TN0379 # 07 Y:1989 07 1989 IMPROVE LUBRICATION PRACTICES $2,421 $1,200 Not Implemented
TN0379 # 08 Y:1989 08 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,954 $3,952 Not Implemented