Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
140
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AR0101 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,857 | $759 | Implemented |
AR0101 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,305 | $350 | Implemented |
AR0101 # 09 Y:1996 | 09 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $36,162 | $0 | Implemented |
AR0101 # 08 Y:1996 | 08 | 1996 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,526 | $1,900 | Implemented |
AR0101 # 07 Y:1996 | 07 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,359 | $3,500 | Not Implemented |
AR0101 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $652 | $70 | Implemented |
AR0101 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,891 | $8,150 | Not Implemented |
AR0101 # 04 Y:1996 | 04 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $817 | $300 | Implemented |
AR0101 # 03 Y:1996 | 03 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,212 | $1,048 | Implemented |
TN0586 # 03 Y:1996 | 03 | 1996 | USE EVAPORATION TO CONCENTRATE MATERIAL | $32,200 | $30,600 | Not Implemented |
TN0596 # 04 Y:1996 | 04 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $37,300 | $61,100 | Not Implemented |
TN0596 # 03 Y:1996 | 03 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $40,800 | $99,260 | Not Implemented |
TN0596 # 02 Y:1996 | 02 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $80,150 | $1,130 | Implemented |
TN0586 # 08 Y:1996 | 08 | 1996 | INSULATE BARE EQUIPMENT | $3,650 | $4,400 | Not Implemented |
TN0586 # 06 Y:1996 | 06 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,800 | $7,350 | Not Implemented |
TN0586 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $39,080 | $7,880 | Implemented |
TN0596 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $580 | $410 | Implemented |
TN0586 # 05 Y:1996 | 05 | 1996 | OPTIMIZE PLANT POWER FACTOR | $25,125 | $60,800 | Not Implemented |
TN0586 # 07 Y:1996 | 07 | 1996 | UPGRADE CONTROLS ON COMPRESSORS | $7,400 | $29,600 | Not Implemented |
TN0586 # 10 Y:1996 | 10 | 1996 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $340 | $260 | Not Implemented |
TN0586 # 04 Y:1996 | 04 | 1996 | TREAT AND REUSE RINSE WATERS | $29,935 | $66,740 | Not Implemented |
TN0586 # 09 Y:1996 | 09 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $4,410 | $0 | Implemented |
TN0586 # 01 Y:1996 | 01 | 1996 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $50,410 | $15,300 | Not Implemented |
TN0596 # 06 Y:1996 | 06 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,170 | $7,000 | Implemented |
TN0596 # 01 Y:1996 | 01 | 1996 | REDESIGN PROCESS | $97,310 | $38,900 | Not Implemented |