Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

18

matching recommendations
Reset
SIC 33 Primary Metal Industries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0567 # 02 Y:2009 02 2009 $3,265 $500 Implemented
AM0567 # 03 Y:2009 03 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,035 $20 Not Implemented
AM0567 # 04 Y:2009 04 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $668 $305 Implemented
AM0567 # 01 Y:2009 01 2009 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $4,925 $1,020 Not Implemented
OK0780 # 14 Y:2009 14 2009 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,341 $0 Implemented
OK0780 # 13 Y:2009 13 2009 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,206 $2,398 Implemented
OK0780 # 12 Y:2009 12 2009 INSTALL WIND POWERED ELECTRIC GENERATOR $1,048,470 $5,670,000 Not Implemented
OK0780 # 11 Y:2009 11 2009 INSTALL / REPAIR INSULATION ON STEAM LINES $1,925 $412 Implemented
OK0780 # 10 Y:2009 10 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,725 $10,000 Implemented
OK0780 # 09 Y:2009 09 2009 INSTALL OCCUPANCY SENSORS $1,517 $274 Not Implemented
OK0780 # 08 Y:2009 08 2009 INSTALL OCCUPANCY SENSORS $312 $732 Not Implemented
OK0780 # 07 Y:2009 07 2009 INSTALL OCCUPANCY SENSORS $31,638 $89,399 Not Implemented
OK0780 # 06 Y:2009 06 2009 INSTALL OCCUPANCY SENSORS $24,432 $100,710 Not Implemented
OK0780 # 05 Y:2009 05 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,642 $21,120 Not Implemented
OK0780 # 04 Y:2009 04 2009 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $853,347 $1,183,200 Not Implemented
OK0780 # 03 Y:2009 03 2009 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $155,286 $17,711 Not Implemented
OK0780 # 02 Y:2009 02 2009 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $66,265 $0 Implemented
OK0780 # 01 Y:2009 01 2009 ADJUST BURNERS FOR EFFICIENT OPERATION $134,300 $0 Implemented