IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

184

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0194 # 02 Y:1993 02 1993 USE SYNTHETIC LUBRICANT $710 $0 Not Implemented
AM0195 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $330 $50 Implemented
AM0194 # 03 Y:1993 03 1993 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $635 $420 Not Implemented
AM0194 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $620 $400 Implemented
AM0195 # 03 Y:1993 03 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $980 $0 Not Implemented
AM0195 # 05 Y:1993 05 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,590 $4,420 Implemented
AM0195 # 02 Y:1993 02 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,500 $0 Implemented
AM0195 # 01 Y:1993 01 1993 OPTIMIZE PLANT POWER FACTOR $21,340 $21,050 Implemented
AM0195 # 06 Y:1993 06 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $680 $580 Implemented
AM0194 # 01 Y:1993 01 1993 OPTIMIZE PLANT POWER FACTOR $23,650 $25,500 Not Implemented
AM0193 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,110 $800 Implemented
AM0193 # 01 Y:1993 01 1993 INSTALL SKYLIGHTS $4,880 $11,100 Not Implemented
AM0193 # 02 Y:1993 02 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,750 $0 Not Implemented
AM0192 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,950 $12,850 Implemented
AM0193 # 09 Y:1993 09 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $130 $195 Not Implemented
AM0193 # 03 Y:1993 03 1993 OPTIMIZE PLANT POWER FACTOR $4,660 $7,500 Implemented
AM0192 # 02 Y:1993 02 1993 OPTIMIZE PLANT POWER FACTOR $3,640 $5,500 Not Implemented
AM0193 # 10 Y:1993 10 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $115 $126 Not Implemented
AM0193 # 07 Y:1993 07 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $220 $0 Implemented
AM0193 # 08 Y:1993 08 1993 PAY UTILITY BILLS ON TIME $200 $0 Not Implemented
AM0193 # 06 Y:1993 06 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $510 $1,550 Not Implemented
AM0192 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $210 $240 Implemented
AM0193 # 05 Y:1993 05 1993 INSTALL TIMERS AND/OR THERMOSTATS $710 $450 Not Implemented
AM0191 # 06 Y:1993 06 1993 PAY UTILITY BILLS ON TIME $700 $0 Implemented
AM0191 # 05 Y:1993 05 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $750 $0 Implemented