Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
13
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0535 # 01 Y:2003 | 01 | 2003 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $372,126 | $3,870,145 | n/a |
MA0535 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $67,147 | $59,125 | n/a |
MA0535 # 03 Y:2003 | 03 | 2003 | REDUCE VENTILATION AIR | $62,192 | $0 | Not Implemented |
MA0535 # 04 Y:2003 | 04 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $56,908 | $84,343 | n/a |
MA0535 # 05 Y:2003 | 05 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,274 | $6,000 | Not Implemented |
MA0535 # 06 Y:2003 | 06 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,836 | $11,700 | n/a |
MA0535 # 07 Y:2003 | 07 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,511 | $5,800 | Not Implemented |
MA0535 # 08 Y:2003 | 08 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,521 | $9,300 | Not Implemented |
MA0535 # 09 Y:2003 | 09 | 2003 | INSULATE BARE EQUIPMENT | $1,685 | $864 | Not Implemented |
MA0535 # 10 Y:2003 | 10 | 2003 | OPTIMIZE PLANT POWER FACTOR | $1,303 | $0 | Implemented |
MA0535 # 11 Y:2003 | 11 | 2003 | USE PHOTOCELL CONTROLS | $1,058 | $1,058 | Not Implemented |
MA0535 # 12 Y:2003 | 12 | 2003 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,038 | $0 | Implemented |
MA0535 # 13 Y:2003 | 13 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $617 | $0 | Implemented |