Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
49
matching recommendationsNAICS | 333 | Machinery Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BS0025 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $444 | $15 | Not Implemented |
BS0025 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $626 | $495 | Not Implemented |
BS0011 # 05 Y:2012 | 05 | 2012 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $8,243 | $900 | Not Implemented |
BS0011 # 06 Y:2012 | 06 | 2012 | INSTALL OCCUPANCY SENSORS | $250 | $600 | Implemented |
BS0011 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,102 | $973 | Implemented |
BS0011 # 03 Y:2012 | 03 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $15,728 | $29,500 | Not Implemented |
BS0011 # 04 Y:2012 | 04 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,878 | $6,670 | Not Implemented |
BS0011 # 02 Y:2012 | 02 | 2012 | REDUCE VENTILATION AIR | $4,008 | $6,725 | Implemented |
UW0004 # 02 Y:2007 | 02 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $7,182 | $25,800 | Implemented |
UW0004 # 04 Y:2007 | 04 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,362 | $968 | Not Implemented |
UW0004 # 03 Y:2007 | 03 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,351 | $5,595 | Not Implemented |
UW0004 # 01 Y:2007 | 01 | 2007 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $13,962 | $8,762 | Implemented |
OR0513 # 01 Y:2007 | 01 | 2007 | REPLACE AIR CURTAIN DOORS WITH SOLID DOORS | $13,700 | $5,000 | Implemented |
OR0513 # 02 Y:2007 | 02 | 2007 | USE PHOTOCELL CONTROLS | $5,900 | $8,000 | Not Implemented |
OR0513 # 03 Y:2007 | 03 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,800 | $300 | Not Implemented |
OR0513 # 04 Y:2007 | 04 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,700 | $1,700 | Implemented |
OR0513 # 05 Y:2007 | 05 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,300 | $800 | Implemented |
OR0498 # 05 Y:2006 | 05 | 2006 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $600 | $400 | Implemented |
OR0498 # 01 Y:2006 | 01 | 2006 | COVER OPEN TANKS | $7,300 | $3,600 | Implemented |
OR0498 # 02 Y:2006 | 02 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,300 | $0 | Not Implemented |
OR0498 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,300 | $2,300 | Implemented |
OR0498 # 04 Y:2006 | 04 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $1,450 | $1,800 | Not Implemented |
OR0498 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,600 | $17,400 | Implemented |
OR0498 # 06 Y:2006 | 06 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,400 | $20,000 | Implemented |