Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

69

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WM0157 # 01 Y:2020 01 2020 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $59,393 $500,000 Not Implemented
WM0157 # 07 Y:2020 07 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,942 $3,194 Implemented
WM0157 # 06 Y:2020 06 2020 USE COMPRESSOR AIR FILTERS $4,984 $19,040 Not Implemented
WM0157 # 05 Y:2020 05 2020 USE SOLAR HEAT TO MAKE ELECTRICTY $12,261 $51,086 Not Implemented
WM0157 # 04 Y:2020 04 2020 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $15,160 $6,952 Not Implemented
WM0157 # 03 Y:2020 03 2020 LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION $18,997 $0 Implemented
WM0157 # 02 Y:2020 02 2020 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $32,506 $160,650 Not Implemented
WM0156 # 07 Y:2020 07 2020 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $1,144 $4,600 Not Implemented
WM0156 # 01 Y:2020 01 2020 USE SOLAR HEAT TO MAKE ELECTRICTY $20,527 $105,000 Not Implemented
WM0156 # 02 Y:2020 02 2020 USE SYNTHETIC LUBRICANT $11,563 $3,300 Not Implemented
WM0156 # 03 Y:2020 03 2020 SHUT OFF AIR CONDITIONING IN WINTER HEATING SEASON $9,593 $0 Not Implemented
WM0156 # 04 Y:2020 04 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,847 $13,133 Not Implemented
WM0156 # 05 Y:2020 05 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,864 $3,527 Implemented
WM0156 # 10 Y:2020 10 2020 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $542 $1,785 Not Implemented
WM0156 # 09 Y:2020 09 2020 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $554 $2,225 Not Implemented
WM0156 # 08 Y:2020 08 2020 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,058 $0 Not Implemented
WM0156 # 06 Y:2020 06 2020 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,164 $0 Implemented
WM0155 # 08 Y:2020 08 2020 INSTALL OCCUPANCY SENSORS $451 $750 Not Implemented
WM0155 # 10 Y:2020 10 2020 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $360 $0 Implemented
WM0155 # 07 Y:2020 07 2020 USE PHOTOCELL CONTROLS $541 $1,075 Not Implemented
WM0155 # 06 Y:2020 06 2020 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,679 $1,750 Not Implemented
WM0155 # 05 Y:2020 05 2020 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,761 $3,855 Not Implemented
WM0155 # 04 Y:2020 04 2020 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $1,791 $15,060 Not Implemented
WM0155 # 03 Y:2020 03 2020 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $2,335 $1,700 Not Implemented
WM0155 # 02 Y:2020 02 2020 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,927 $8,716 Not Implemented