Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,746

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0237 # 02 Y:1984 02 1984 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $402 $0 Not Implemented
TN0237 # 01 Y:1984 01 1984 RECOVER WASTE HEAT FROM EQUIPMENT $1,114 $2,500 Not Implemented
TN0234 # 04 Y:1984 04 1984 PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT $233 $408 Not Implemented
TN0234 # 03 Y:1984 03 1984 INSTALL SET-BACK TIMERS $2,524 $0 Implemented
TN0234 # 02 Y:1984 02 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,385 $30,392 Not Implemented
TN0234 # 01 Y:1984 01 1984 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $6,646 $30,000 Not Implemented
GT0237 # 01 Y:1984 01 1984 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $7,160 $2,000 Not Implemented
GT0237 # 02 Y:1984 02 1984 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $574 $970 Implemented
GT0237 # 03 Y:1984 03 1984 REPAIR AND ELIMINATE STEAM LEAKS $1,730 $100 Implemented
CO0015 # 12 Y:1984 12 1984 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $1,237 $3,000 Not Implemented
CO0015 # 11 Y:1984 11 1984 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $335 $250 Implemented
CO0015 # 10 Y:1984 10 1984 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,676 $5,000 Implemented
CO0015 # 09 Y:1984 09 1984 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY $220 $100 Not Implemented
CO0015 # 08 Y:1984 08 1984 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $293 $120 Not Implemented
CO0015 # 07 Y:1984 07 1984 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $1,240 $103 Not Implemented
CO0015 # 06 Y:1984 06 1984 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $791 $230 Implemented
CO0015 # 05 Y:1984 05 1984 INSTALL TIMERS AND/OR THERMOSTATS $5,808 $4,000 Not Implemented
CO0015 # 04 Y:1984 04 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $694 $1,127 Implemented
CO0015 # 03 Y:1984 03 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $290 $50 Implemented
CO0015 # 02 Y:1984 02 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $300 $300 Implemented
CO0015 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $963 $908 Implemented
CO0014 # 05 Y:1984 05 1984 USE DEMAND CONTROLLER OR LOAD SHEDDER $4,970 $1,000 Implemented
CO0014 # 04 Y:1984 04 1984 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $730 $2,500 Not Implemented
CO0014 # 03 Y:1984 03 1984 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $74 $135 Implemented
CO0014 # 02 Y:1984 02 1984 INSTALL / REPAIR INSULATION ON STEAM LINES $561 $300 Implemented