Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1990 |
Principal Product | TREATED LUMBER |
NAICS | n/a |
SIC | 2491 - Wood Preserving |
Sales | $10,000,000-$50,000,000 |
# of Employees | 95 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 1,800 Thousand Feet |
Production Hrs. Annual | 8,712 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $137,743 | 1,986,811 | kWh | $0.07 |
Natural Gas | $3,575 | 968 | MMBtu | $3.69 |
Wood | $42,720 | 489,856 | MMBtu | $0.09 |
TOTAL ENERGY COSTS | $184,038 | |||
RECOMMENDED SAVINGS* | $36,953 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,173 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Wood | Electricity Usage | Natural Gas | Wood | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $12,075 Cost: $50,000 |
$12,075 | 215,416 | - | - | - | - |
$12,075 215,416 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,720 Cost: $1,100 |
$4,720 | 94,666 | - | - | - | - |
$4,720 94,666 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2121 INCREASE AMOUNT OF CONDENSATE RETURNED |
Savings: $4,500 Cost: - |
- | - | - | - | $4,500 | 8,345 |
- - kWh |
- - MMBtu |
$4,500 8,345 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $4,080 Cost: $16,400 |
- | - | - | - | $4,080 | 7,560 |
- - kWh |
- - MMBtu |
$4,080 7,560 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2162 REDUCE EXCESS STEAM BLEEDING |
Savings: $3,575 Cost: $3,750 |
- | - | $3,575 | 1,000 | - | - |
- - kWh |
$3,575 1,000 MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,030 Cost: - |
$2,030 | 55,393 | - | - | - | - |
$2,030 55,393 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,800 Cost: $3,500 |
$1,800 | - | - | - | - | - |
$1,800 - kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $1,600 Cost: $2,400 |
- | - | - | - | $1,600 | 3,000 |
- - kWh |
- - MMBtu |
$1,600 3,000 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4312 IMPROVE LUBRICATION PRACTICES |
Savings: $1,600 Cost: - |
$1,600 | 32,239 | - | - | - | - |
$1,600 32,239 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $602 Cost: $2,665 |
- | - | - | - | $602 | 1,115 |
- - kWh |
- - MMBtu |
$602 1,115 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $155 Cost: $319 |
$155 | 2,052 | - | - | - | - |
$155 2,052 kWh |
- - MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $216 Cost: $875 |
- | - | - | - | $216 | 400 |
- - kWh |
- - MMBtu |
$216 400 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $36,953 Cost: $81,009 |
$22,380 | 399,766 | $3,575 | 1,000 | $10,998 | 20,420 | $22,380 399,766 kWh |
$3,575 1,000 MMBtu |
$10,998 20,420 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,173 Cost: $27,259 |
$6,675 | 96,718 | - | - | $6,498 | 12,075 | $6,675 96,718 kWh |
- - MMBtu |
$6,498 12,075 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Wood | Electricity Usage | Natural Gas | Wood |