Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 1991
Principal Product ALUMINUM ALLOY AIRCRAFT
NAICS n/a
SIC 3365 - Aluminum Foundries
Sales $10,000,000-$50,000,000
# of Employees 140
Plant Area (Sq.Ft.) 0
Annual Production 10,000,000 Pieces
Production Hrs. Annual 5,760
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $219,903 4,303,341 kWh $0.05
Natural Gas $45,151 10,875 MMBtu $4.15
TOTAL ENERGY COSTS $265,054
RECOMMENDED SAVINGS* $10,175 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$6,600
Cost:
$12,670
- - $6,600 1,590 - - -
-
kWh
$6,600
1,590
MMBtu
-
-
$
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,770
Cost:
$845
$1,770 72,392 - - - - $1,770
72,392
kWh
-
-
MMBtu
-
-
$
03: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$750
Cost:
$627
$750 - - - - - $750
-
kWh
-
-
MMBtu
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$690
Cost:
$300
$690 28,136 - - - - $690
28,136
kWh
-
-
MMBtu
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$120
Cost:
-
$190 2,638 - - $(-70) - $190
2,638
kWh
-
-
MMBtu
$(-70)
-
$
06: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER Savings:
$245
Cost:
$635
- - $245 59 - - -
-
kWh
$245
59
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$10,175
Cost:
$15,077
$3,400 103,166 $6,845 1,649 $(-70) - $3,400
103,166
kWh
$6,845
1,649
MMBtu
$(-70)
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes