IAC logo
IAC Assessment: AM0156
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0156
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 1992
Principal Product SALT FOR ANIMAL CONSUMPTION
NAICS n/a
SIC 2048 - Prepared Feeds, Nec
Sales $5,000,000-$10,000,000
# of Employees 51
Plant Area (Sq.Ft.) 0
Annual Production 113,000 Tons
Production Hrs. Annual 4,482
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $210,050 3,135,991 kWh $0.07
TOTAL ENERGY COSTS $210,050
RECOMMENDED SAVINGS* $31,872 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $22,182
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Electricity Usage Administrative Changes
$ kWh $ $
01: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION Savings:
$8,260
Cost:
-
$10,850 - $(-2,590) - $10,850
-
kWh
$(-2,590)
-
$
02: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$10,125
Cost:
$1,500
$10,125 - - - $10,125
-
kWh
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,117
Cost:
$3,200
$3,108 51,583 $2,009 - $3,108
51,583
kWh
$2,009
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,040
Cost:
$860
$4,040 106,975 - - $4,040
106,975
kWh
-
-
$
05: 2.6232 INSTALL SET-BACK TIMERS Savings:
$2,900
Cost:
-
$2,900 76,202 - - $2,900
76,202
kWh
-
-
$
06: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$1,430
Cost:
-
$1,430 26,964 - - $1,430
26,964
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$31,872
Cost:
$5,560
$32,453 261,724 $(-581) - $32,453
261,724
kWh
$(-581)
-
$
TOTAL IMPLEMENTED Savings:
$22,182
Cost:
$5,560
$20,173 234,760 $2,009 - $20,173
234,760
kWh
$2,009
-
$
Savings
Cost
$ kWh $ $
Electricity Usage Administrative Changes Electricity Usage Administrative Changes