Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1996 |
Principal Product | Agricultural gasoline-powered sprayers |
NAICS | n/a |
SIC | 3523 - Farm Machinery And Equipment |
Sales | $5,000,000-$10,000,000 |
# of Employees | 38 |
Plant Area (Sq.Ft.) | 65,000 |
Annual Production | 6,000 Pieces |
Production Hrs. Annual | 2,202 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $30,383 | 587,046 | kWh | $0.05 |
Electricity Demand | $25,605 | 3,151 | kW-months/year | $8.13 |
Electricity Fees | $170 | - | $ | - |
Natural Gas | $15,608 | 2,883 | MMBtu | $5.41 |
TOTAL ENERGY COSTS | $75,096 | |||
RECOMMENDED SAVINGS* | $7,820 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,820 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,670 Cost: $140 |
$820 | 18,171 | $850 | 86 | - | - | - | - |
$820 18,171 kWh |
$850 86 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,320 Cost: $510 |
$1,320 | 29,308 | - | - | - | - | - | - |
$1,320 29,308 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $640 Cost: $250 |
$70 | 1,758 | $20 | 2 | - | - | $550 | - |
$70 1,758 kWh |
$20 2 kW-months/year |
- - lb |
$550 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $440 Cost: $300 |
$440 | 9,672 | - | - | - | - | - | - |
$440 9,672 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $420 Cost: $270 |
$210 | 4,689 | $210 | 21 | - | - | - | - |
$210 4,689 kWh |
$210 21 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $3,330 Cost: $500 |
- | - | - | - | $3,330 | 1,760 | - | - |
- - kWh |
- - kW-months/year |
$3,330 1,760 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $7,820 Cost: $1,970 |
$2,860 | 63,598 | $1,080 | 109 | $3,330 | 1,760 | $550 | - | $2,860 63,598 kWh |
$1,080 109 kW-months/year |
$3,330 1,760 lb |
$550 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,820 Cost: $1,970 |
$2,860 | 63,598 | $1,080 | 109 | $3,330 | 1,760 | $550 | - | $2,860 63,598 kWh |
$1,080 109 kW-months/year |
$3,330 1,760 lb |
$550 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes |