Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1996 |
Principal Product | Titanium & inconel aircraft engine components |
NAICS | n/a |
SIC | 3724 - Aircraft Engines And Engine Parts |
Sales | $10,000,000-$50,000,000 |
# of Employees | 128 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 600 Pieces |
Production Hrs. Annual | 5,134 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $420,896 | 10,061,548 | kWh | $0.04 |
Electricity Demand | $47,449 | 28,584 | kW-months/year | $1.66 |
Natural Gas | $30,856 | 10,405 | MMBtu | $2.97 |
TOTAL ENERGY COSTS | $499,201 | |||
RECOMMENDED SAVINGS* | $39,594 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $38,854 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $28,900 Cost: - |
$28,900 | 688,746 | - | - | - | - | - | - | - | - |
$28,900 688,746 kWh |
- - kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,295 Cost: $1,070 |
$280 | 6,741 | $15 | 9 | - | - | - | - | $3,000 | - |
$280 6,741 kWh |
$15 9 kW-months/year |
- - Tgal |
- - lb |
$3,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,290 Cost: $700 |
$1,290 | 30,774 | - | - | - | - | - | - | - | - |
$1,290 30,774 kWh |
- - kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $860 Cost: $1,160 |
$710 | 16,706 | $150 | 90 | - | - | - | - | - | - |
$710 16,706 kWh |
$150 90 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $694 Cost: $520 |
$650 | 15,533 | $44 | 26 | - | - | - | - | - | - |
$650 15,533 kWh |
$44 26 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $740 Cost: - |
$700 | 14,947 | $40 | 24 | - | - | - | - | - | - |
$700 14,947 kWh |
$40 24 kW-months/year |
- - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $2,230 Cost: $500 |
- | - | - | - | $2,230 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,230 - Tgal |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.7198 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT |
Savings: $905 Cost: $110 |
- | - | - | - | - | - | $905 | 1,885 | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$905 1,885 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $680 Cost: - |
- | - | - | - | - | - | $680 | 1,226 | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$680 1,226 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $39,594 Cost: $4,060 |
$32,530 | 773,447 | $249 | 149 | $2,230 | - | $1,585 | 3,111 | $3,000 | - | $32,530 773,447 kWh |
$249 149 kW-months/year |
$2,230 - Tgal |
$1,585 3,111 lb |
$3,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $38,854 Cost: $4,060 |
$31,830 | 758,500 | $209 | 125 | $2,230 | - | $1,585 | 3,111 | $3,000 | - | $31,830 758,500 kWh |
$209 125 kW-months/year |
$2,230 - Tgal |
$1,585 3,111 lb |
$3,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Administrative Changes | Electricity Usage | Electricity Demand | Water Disposal | Solid Waste (non-haz) | Administrative Changes |