Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1996 |
Principal Product | Tank heads and mold boards |
NAICS | n/a |
SIC | 3443 - Fabricated Plate Work (boiler Shops) |
Sales | $50,000,000-$100,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 122,500 Pieces |
Production Hrs. Annual | 5,020 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $163,643 | 6,551,876 | kWh | $0.02 |
Electricity Demand | $147,132 | 17,479 | kW-months/year | $8.42 |
Natural Gas | $546,052 | 253,787 | MMBtu | $2.15 |
TOTAL ENERGY COSTS | $856,827 | |||
RECOMMENDED SAVINGS* | $50,244 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $31,592 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $18,652 Cost: - |
- | - | $18,652 | 2,788 | - | - |
- - kWh |
$18,652 2,788 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $15,365 Cost: $9,000 |
- | - | $15,365 | 2,297 | - | - |
- - kWh |
$15,365 2,297 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $340 Cost: $790 |
$180 | 6,155 | $160 | 24 | - | - |
$180 6,155 kWh |
$160 24 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,600 Cost: $1,000 |
$5,600 | 193,435 | - | - | - | - |
$5,600 193,435 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $760 Cost: - |
$330 | 11,430 | $430 | 65 | - | - |
$330 11,430 kWh |
$430 65 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $640 Cost: $100 |
$310 | 10,551 | $330 | 49 | - | - |
$310 10,551 kWh |
$330 49 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.7131 USE A RAG RECYCLE SERVICE |
Savings: $5,340 Cost: $75 |
- | - | - | - | $5,340 | 4,050 |
- - kWh |
- - kW-months/year |
$5,340 4,050 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.7198 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT |
Savings: $2,637 Cost: $110 |
- | - | - | - | $2,637 | 86,173 |
- - kWh |
- - kW-months/year |
$2,637 86,173 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.1182 MAKE A NEW BY-PRODUCT |
Savings: $910 Cost: - |
- | - | - | - | $910 | 3,000 |
- - kWh |
- - kW-months/year |
$910 3,000 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $50,244 Cost: $11,075 |
$6,420 | 221,571 | $34,937 | 5,223 | $8,887 | 93,223 | $6,420 221,571 kWh |
$34,937 5,223 kW-months/year |
$8,887 93,223 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $31,592 Cost: $11,075 |
$6,420 | 221,571 | $16,285 | 2,435 | $8,887 | 93,223 | $6,420 221,571 kWh |
$16,285 2,435 kW-months/year |
$8,887 93,223 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Solid Waste (non-haz) |