Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1997 |
Principal Product | Folding paperboard boxes and sanitary food containers |
NAICS | n/a |
SIC | 2657 - Folding Paperboard Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 185 |
Plant Area (Sq.Ft.) | 102,000 |
Annual Production | 140,000 Tons |
Production Hrs. Annual | 8,712 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $206,376 | 6,434,349 | kWh | $0.03 |
Electricity Demand | $95,494 | 11,351 | kW-months/year | $8.41 |
Electricity Fees | $(-12,606) | - | $ | - |
TOTAL ENERGY COSTS | $289,264 | |||
RECOMMENDED SAVINGS* | $22,435 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $14,055 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $10,800 Cost: $1,000 |
$10,800 | 468,933 | - | - | - | - | - | - | - | - |
$10,800 468,933 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $780 Cost: $1,370 |
$390 | 18,464 | $390 | 32 | - | - | - | - | - | - |
$390 18,464 kWh |
$390 32 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $3,330 Cost: - |
- | - | - | - | $3,330 | 526,000 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,330 526,000 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7314 REDUCE VENTILATION AIR |
Savings: $2,430 Cost: $2,100 |
$510 | 39,273 | $1,920 | 160 | - | - | - | - | - | - |
$510 39,273 kWh |
$1,920 160 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,570 Cost: $150 |
$1,570 | 68,288 | - | - | - | - | - | - | - | - |
$1,570 68,288 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,020 Cost: $475 |
$100 | 2,931 | $50 | 4 | - | - | $870 | - | - | - |
$100 2,931 kWh |
$50 4 kW-months/year |
- - lb |
$870 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $940 Cost: $150 |
$940 | 41,032 | - | - | - | - | - | - | - | - |
$940 41,032 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7314 REDUCE VENTILATION AIR |
Savings: $820 Cost: $30 |
$170 | 13,189 | $650 | 54 | - | - | - | - | - | - |
$170 13,189 kWh |
$650 54 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $745 Cost: $1,490 |
- | - | - | - | - | - | - | - | $745 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$745 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $22,435 Cost: $6,765 |
$14,480 | 652,110 | $3,010 | 250 | $3,330 | 526,000 | $870 | - | $745 | - | $14,480 652,110 kWh |
$3,010 250 kW-months/year |
$3,330 526,000 lb |
$870 - $ |
$745 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $14,055 Cost: $2,790 |
$13,310 | 578,253 | - | - | - | - | - | - | $745 | - | $13,310 578,253 kWh |
- - kW-months/year |
- - lb |
- - $ |
$745 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Administrative Changes |