Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2001 |
Principal Product | Oil & Water Well Screens |
NAICS | n/a |
SIC | 3533 - Oil And Gas Field Machinery |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 262 Thousand Feet |
Production Hrs. Annual | 0 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $95,040 | 1,529,050 | kWh | $0.06 |
Electricity Demand | $15,973 | 5,512 | kW-months/year | $2.90 |
Natural Gas | $29,800 | 5,166 | MMBtu | $5.77 |
TOTAL ENERGY COSTS | $140,813 | |||
RECOMMENDED SAVINGS* | $46,145 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $30,625 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $15,625 Cost: $1,250 |
$15,625 | 258,300 | - | - | - | - | - | - | - | - |
$15,625 258,300 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $4,760 Cost: $4,500 |
- | - | $4,760 | 408 | - | - | - | - | - | - |
- - kWh |
$4,760 408 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.3131 USE EVAPORATION TO CONCENTRATE MATERIAL |
Savings: $4,480 Cost: $7,000 |
- | - | - | - | - | - | $4,480 | 106,520 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,480 106,520 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7145 INSTALL SKYLIGHTS |
Savings: $3,400 Cost: $9,860 |
$3,400 | 67,700 | - | - | - | - | - | - | - | - |
$3,400 67,700 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,340 Cost: $5,705 |
$2,610 | 40,685 | $730 | 104 | - | - | - | - | - | - |
$2,610 40,685 kWh |
$730 104 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,450 Cost: $4,330 |
- | - | $2,450 | 448 | - | - | - | - | - | - |
- - kWh |
$2,450 448 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $2,300 Cost: - |
$2,300 | 32,300 | - | - | - | - | - | - | - | - |
$2,300 32,300 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $2,280 Cost: - |
$2,280 | 32,060 | - | - | - | - | - | - | - | - |
$2,280 32,060 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING |
Savings: $1,640 Cost: $240 |
- | - | - | - | $1,640 | 286 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,640 286 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,250 Cost: - |
- | - | - | - | $1,250 | 218 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,250 218 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,220 Cost: $2,000 |
$1,070 | 15,000 | $150 | 28 | - | - | - | - | - | - |
$1,070 15,000 kWh |
$150 28 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7145 INSTALL SKYLIGHTS |
Savings: $1,000 Cost: $3,170 |
$1,000 | 14,100 | - | - | - | - | - | - | - | - |
$1,000 14,100 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $975 Cost: - |
- | - | - | - | - | - | - | - | $975 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$975 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $655 Cost: - |
$530 | 7,880 | $125 | 20 | - | - | - | - | - | - |
$530 7,880 kWh |
$125 20 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $395 Cost: $1,875 |
- | - | $395 | 72 | - | - | - | - | - | - |
- - kWh |
$395 72 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $375 Cost: - |
$260 | 3,360 | $115 | 10 | - | - | - | - | - | - |
$260 3,360 kWh |
$115 10 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $46,145 Cost: $39,930 |
$29,075 | 471,385 | $8,725 | 1,090 | $2,890 | 504 | $4,480 | 106,520 | $975 | - | $29,075 471,385 kWh |
$8,725 1,090 kW-months/year |
$2,890 504 MMBtu |
$4,480 106,520 Tgal |
$975 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $30,625 Cost: $13,955 |
$23,075 | 366,705 | $845 | 114 | $1,250 | 218 | $4,480 | 106,520 | $975 | - | $23,075 366,705 kWh |
$845 114 kW-months/year |
$1,250 218 MMBtu |
$4,480 106,520 Tgal |
$975 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes |