Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2016
Principal Product plumbing fittings
NAICS 332913 - Plumbing Fixture Fitting and Trim Manufacturing
SIC 3432 - Plumbing Fixture Fittings And Trim
Sales $100,000,000-$500,000,000
# of Employees 280
Plant Area (Sq.Ft.) 163,000
Annual Production 365,000,000 Pieces
Production Hrs. Annual 7,248
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $386,011 8,104,800 kWh $0.05
Electricity Demand $156,114 19,475 kW-months/year $8.02
Electricity Fees $11,843 - $ -
Natural Gas $62,170 15,736 MMBtu $3.95
TOTAL ENERGY COSTS $724,549
RECOMMENDED SAVINGS* $71,469 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$54,900
Cost:
$270,000
$30,000 624,000 $24,900 3,100 - - $30,000
624,000
kWh
$24,900
3,100
kW-months/year
-
-
MMBtu
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$6,580
Cost:
$11
$5,060 106,200 $1,520 190 - - $5,060
106,200
kWh
$1,520
190
kW-months/year
-
-
MMBtu
03: 2.7264 INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION Savings:
$4,142
Cost:
$63
$686 14,400 $2,780 347 $676 130 $686
14,400
kWh
$2,780
347
kW-months/year
$676
130
MMBtu
04: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS Savings:
$2,700
Cost:
-
- - $2,700 335 - - -
-
kWh
$2,700
335
kW-months/year
-
-
MMBtu
05: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$1,110
Cost:
-
$760 15,968 $350 44 - - $760
15,968
kWh
$350
44
kW-months/year
-
-
MMBtu
06: 2.2113 REPAIR OR REPLACE STEAM TRAPS Savings:
$647
Cost:
$520
- - - - $647 124 -
-
kWh
-
-
kW-months/year
$647
124
MMBtu
07: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$630
Cost:
$1,450
$630 13,252 - - - - $630
13,252
kWh
-
-
kW-months/year
-
-
MMBtu
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$400
Cost:
$560
$313 6,590 $87 11 - - $313
6,590
kWh
$87
11
kW-months/year
-
-
MMBtu
09: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$360
Cost:
$460
$360 7,510 - - - - $360
7,510
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$71,469
Cost:
$273,064
$37,809 787,920 $32,337 4,027 $1,323 254 $37,809
787,920
kWh
$32,337
4,027
kW-months/year
$1,323
254
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas