Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2016 |
Principal Product | Fertilizer |
NAICS | 325314 - Fertilizer (Mixing Only) Manufacturing |
SIC | 2875 - Fertilizers, Mixing Only |
Sales | $100,000,000-$500,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 197,000 |
Annual Production | 300,000 Tons |
Production Hrs. Annual | 8,736 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $320,548 | 5,326,845 | kWh | $0.06 |
Electricity Demand | $53,235 | 10,898 | kW-months/year | $4.88 |
Electricity Fees | $10,872 | - | $ | - |
Natural Gas | $26,847 | 3,908 | MMBtu | $6.87 |
TOTAL ENERGY COSTS | $411,502 | |||
RECOMMENDED SAVINGS* | $105,010 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $60,410 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $44,600 Cost: $52,500 |
$38,800 | 680,500 | $5,800 | 940 |
$38,800 680,500 kWh |
$5,800 940 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $24,300 Cost: $11,400 |
$24,300 | 425,700 | - | - |
$24,300 425,700 kWh |
- - kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.423 MOVE PRODUCT USING MECHANICAL MEANS |
Savings: $23,300 Cost: $66,600 |
$14,700 | 257,800 | $8,600 | 1,400 |
$14,700 257,800 kWh |
$8,600 1,400 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,480 Cost: $445 |
$4,140 | 72,660 | $1,340 | 216 |
$4,140 72,660 kWh |
$1,340 216 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3134 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION |
Savings: $3,830 Cost: $1,000 |
- | - | $3,830 | 620 |
- - kWh |
$3,830 620 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $3,500 Cost: $195 |
$3,500 | 61,700 | - | - |
$3,500 61,700 kWh |
- - kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $105,010 Cost: $132,140 |
$85,440 | 1,498,360 | $19,570 | 3,176 | $85,440 1,498,360 kWh |
$19,570 3,176 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $60,410 Cost: $79,640 |
$46,640 | 817,860 | $13,770 | 2,236 | $46,640 817,860 kWh |
$13,770 2,236 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand |