Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2016 |
Principal Product | Solar panels |
NAICS | 334413 - Semiconductor and Related Device Manufacturing |
SIC | 3674 - Semiconductors And Related Devices |
Sales | $100,000,000-$500,000,000 |
# of Employees | 410 |
Plant Area (Sq.Ft.) | 188,180 |
Annual Production | 569,492 Pieces |
Production Hrs. Annual | 8,688 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,868,635 | 32,214,470 | kWh | $0.06 |
Electricity Demand | $541,759 | 56,623 | kW-months/year | $9.57 |
Electricity Fees | $183,694 | - | $ | - |
Natural Gas | $63,010 | 9,896 | MMBtu | $6.37 |
TOTAL ENERGY COSTS | $2,657,098 | |||
RECOMMENDED SAVINGS* | $702,519 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $74,009 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Usage | Electricity Usage | Electricity Demand | Water Usage | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7292 LOWER CEILING TO REDUCE CONDITIONED SPACE |
Savings: $566,490 Cost: $1,145,213 |
$464,800 | 7,496,490 | $101,690 | 10,560 | - | - |
$464,800 7,496,490 kWh |
$101,690 10,560 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $53,960 Cost: - |
- | - | - | - | $53,960 | 8,644 |
- - kWh |
- - kW-months/year |
$53,960 8,644 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9113 USE SOLAR HEAT FOR HEAT |
Savings: $31,594 Cost: $151,288 |
$23,818 | 384,167 | $7,776 | 807 | - | - |
$23,818 384,167 kWh |
$7,776 807 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $24,530 Cost: $50,830 |
$19,570 | 315,705 | $4,960 | 515 | - | - |
$19,570 315,705 kWh |
$4,960 515 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $12,750 Cost: $50 |
$10,500 | 169,355 | $2,250 | 234 | - | - |
$10,500 169,355 kWh |
$2,250 234 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2211 USE OPTIMUM TEMPERATURE |
Savings: $8,060 Cost: $9,230 |
$8,060 | 130,000 | - | - | - | - |
$8,060 130,000 kWh |
- - kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM |
Savings: $4,830 Cost: $4,560 |
$4,830 | 78,000 | - | - | - | - |
$4,830 78,000 kWh |
- - kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $305 Cost: - |
$305 | 4,940 | - | - | - | - |
$305 4,940 kWh |
- - kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $702,519 Cost: $1,361,171 |
$531,883 | 8,578,657 | $116,676 | 12,116 | $53,960 | 8,644 | $531,883 8,578,657 kWh |
$116,676 12,116 kW-months/year |
$53,960 8,644 Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $74,009 Cost: $206,728 |
$59,023 | 952,167 | $14,986 | 1,556 | - | - | $59,023 952,167 kWh |
$14,986 1,556 kW-months/year |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Usage | Electricity Usage | Electricity Demand | Water Usage |