Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Arkansas
Assessment Year 1994
Principal Product Commerical Lumber
NAICS n/a
SIC 2421 - Sawmills And Planing Mills, General
Sales $10,000,000-$50,000,000
# of Employees 236
Plant Area (Sq.Ft.) 200,000
Annual Production 100,000,000 Thousand Feet
Production Hrs. Annual 4,171
Location (State) AR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $712,082 9,394,197 kWh $0.08
Natural Gas $588,398 263,036 MMBtu $2.24
TOTAL ENERGY COSTS $1,300,480
RECOMMENDED SAVINGS* $108,861 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $21,236
#|Description Savings
Cost
Status Electricity Usage Natural Gas Personnel Changes Electricity Usage Natural Gas Personnel Changes
$ kWh $ MMBtu $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$6,142
Cost:
$8,050
$6,142 80,891 - - - - $6,142
80,891
kWh
-
-
MMBtu
-
-
$
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$7,927
Cost:
$1,991
$7,927 104,631 - - - - $7,927
104,631
kWh
-
-
MMBtu
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,836
Cost:
$327
$1,836 24,326 - - - - $1,836
24,326
kWh
-
-
MMBtu
-
-
$
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$2,232
Cost:
$1,100
$2,232 29,308 - - - - $2,232
29,308
kWh
-
-
MMBtu
-
-
$
05: 2.4134 REPLACE ELECTRIC MOTOR WITH FOSSIL FUEL ENGINE Savings:
$87,625
Cost:
$54,000
$122,352 1,613,716 $(-18,727) (-8,360) $(-16,000) - $122,352
1,613,716
kWh
$(-18,727)
(-8,360)
MMBtu
$(-16,000)
-
$
06: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$3,099
Cost:
$459
- - $3,099 1,383 - - -
-
kWh
$3,099
1,383
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$108,861
Cost:
$65,927
$140,489 1,852,872 $(-15,628) (-6,977) $(-16,000) - $140,489
1,852,872
kWh
$(-15,628)
(-6,977)
MMBtu
$(-16,000)
-
$
TOTAL IMPLEMENTED Savings:
$21,236
Cost:
$11,927
$18,137 239,156 $3,099 1,383 - - $18,137
239,156
kWh
$3,099
1,383
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Personnel Changes Electricity Usage Natural Gas Personnel Changes