Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Arkansas |
---|---|
Assessment Year | 1995 |
Principal Product | Steel Pipe Couplings |
NAICS | n/a |
SIC | 3498 - Fabricated Pipe And Fittings |
Sales | $50,000,000-$100,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 130,000 |
Annual Production | 24,700,000 Pounds |
Production Hrs. Annual | 7,509 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $356,023 | 6,283,118 | kWh | $0.06 |
Natural Gas | $29,284 | 7,578 | MMBtu | $3.86 |
TOTAL ENERGY COSTS | $393,532 | |||
RECOMMENDED SAVINGS* | $33,784 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $32,816 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Natural Gas | Water Disposal | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | Tgal | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $997 Cost: $380 |
$997 | 14,947 | - | - | - | - | - | - |
$997 14,947 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $14,786 Cost: $900 |
$14,786 | 296,600 | - | - | - | - | - | - |
$14,786 296,600 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,829 Cost: - |
$1,829 | 40,152 | - | - | - | - | - | - |
$1,829 40,152 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $490 Cost: $1,000 |
- | - | $490 | 127 | - | - | - | - |
- - kWh |
$490 127 MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,615 Cost: $300 |
$3,615 | 73,271 | - | - | - | - | - | - |
$3,615 73,271 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,364 Cost: $400 |
$1,364 | 27,550 | - | - | - | - | - | - |
$1,364 27,550 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $8,172 Cost: $16,900 |
$8,172 | 141,852 | - | - | - | - | - | - |
$8,172 141,852 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $968 Cost: $400 |
$968 | 19,637 | - | - | - | - | - | - |
$968 19,637 kWh |
- - MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $420 Cost: $100 |
- | - | $420 | 109 | - | - | - | - |
- - kWh |
$420 109 MMBtu |
- - Tgal |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.4151 MINIMIZE WATER USAGE |
Savings: $1,143 Cost: $100 |
- | - | - | - | $587 | 248,000 | $556 | - |
- - kWh |
- - MMBtu |
$587 248,000 Tgal |
$556 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $33,784 Cost: $20,480 |
$31,731 | 614,009 | $910 | 236 | $587 | 248,000 | $556 | - | $31,731 614,009 kWh |
$910 236 MMBtu |
$587 248,000 Tgal |
$556 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $32,816 Cost: $20,080 |
$30,763 | 594,372 | $910 | 236 | $587 | 248,000 | $556 | - | $30,763 594,372 kWh |
$910 236 MMBtu |
$587 248,000 Tgal |
$556 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | Tgal | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Natural Gas | Water Disposal | Water Consumption |