Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Arkansas |
---|---|
Assessment Year | 1996 |
Principal Product | Support Hardware |
NAICS | n/a |
SIC | 3644 - Noncurrent-carrying Wiring Devices |
Sales | $50,000,000-$100,000,000 |
# of Employees | 267 |
Plant Area (Sq.Ft.) | 404,000 |
Annual Production | 6,000,000 Pieces |
Production Hrs. Annual | 6,257 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $249,792 | 8,390,387 | kWh | $0.03 |
Electricity Demand | $98,694 | 18,539 | kW-months/year | $5.32 |
Natural Gas | $34,737 | 11,291 | MMBtu | $3.08 |
TOTAL ENERGY COSTS | $416,590 | |||
RECOMMENDED SAVINGS* | $12,165 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,967 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,369 Cost: $20 |
$1,013 | 34,877 | $356 | 67 | - | - |
$1,013 34,877 kWh |
$356 67 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,617 Cost: $450 |
$2,024 | 70,633 | $593 | 112 | - | - |
$2,024 70,633 kWh |
$593 112 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,695 Cost: $5,860 |
$2,560 | 88,218 | $1,135 | 214 | - | - |
$2,560 88,218 kWh |
$1,135 214 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $386 Cost: - |
$228 | 7,913 | $158 | 30 | - | - |
$228 7,913 kWh |
$158 30 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $872 Cost: $624 |
$562 | 19,343 | $310 | 68 | - | - |
$562 19,343 kWh |
$310 68 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,326 Cost: $2,326 |
$1,702 | 58,617 | $624 | 118 | - | - |
$1,702 58,617 kWh |
$624 118 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.7311 MAINTAIN MACHINES TO REDUCE LEAKS |
Savings: $900 Cost: $300 |
- | - | - | - | $900 | 90 |
- - kWh |
- - kW-months/year |
$900 90 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $12,165 Cost: $9,580 |
$8,089 | 279,601 | $3,176 | 609 | $900 | 90 | $8,089 279,601 kWh |
$3,176 609 kW-months/year |
$900 90 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,967 Cost: $6,630 |
$5,825 | 201,641 | $2,242 | 423 | $900 | 90 | $5,825 201,641 kWh |
$2,242 423 kW-months/year |
$900 90 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Electricity Usage | Electricity Demand | Other Liquid (non-haz) |