Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Arkansas |
---|---|
Assessment Year | 1999 |
Principal Product | Unsupported plastics film and sheets |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 30,000 |
Annual Production | 25,000,000 Pounds |
Production Hrs. Annual | 2,912 |
Location (State) | TN |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $335,868 | 10,322,978 | kWh | $0.03 |
Electricity Demand | $192,151 | 18,844 | kW-months/year | $10.20 |
Natural Gas | $107,919 | 32,582 | MMBtu | $3.31 |
TOTAL ENERGY COSTS | $641,903 | |||
RECOMMENDED SAVINGS* | $47,615 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,698 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,698 Cost: $6,378 |
$1,601 | 48,652 | $1,097 | 108 | - | - | - | - |
$1,601 48,652 kWh |
$1,097 108 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,846 Cost: $2,882 |
$1,223 | 37,222 | $623 | 61 | - | - | - | - |
$1,223 37,222 kWh |
$623 61 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4155 METER WASTE WATER |
Savings: $672 Cost: $500 |
- | - | - | - | $672 | 120,000 | - | - |
- - kWh |
- - kW-months/year |
$672 120,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $42,399 Cost: $1,284 |
- | - | - | - | - | - | $42,399 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$42,399 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $47,615 Cost: $11,044 |
$2,824 | 85,874 | $1,720 | 169 | $672 | 120,000 | $42,399 | - | $2,824 85,874 kWh |
$1,720 169 kW-months/year |
$672 120,000 Tgal |
$42,399 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,698 Cost: $6,378 |
$1,601 | 48,652 | $1,097 | 108 | - | - | - | - | $1,601 48,652 kWh |
$1,097 108 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes |