Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Arkansas |
---|---|
Assessment Year | 2000 |
Principal Product | Oil Processing Catalysts and Adsorbents |
NAICS | n/a |
SIC | 2819 - Industrial Inorganic Chemicals, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 52 |
Plant Area (Sq.Ft.) | 95,000 |
Annual Production | 11,000 Pounds |
Production Hrs. Annual | 8,736 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $333,930 | 11,837,339 | kWh | $0.03 |
Electricity Demand | $263,599 | 23,258 | kW-months/year | $11.33 |
Natural Gas | $711,597 | 212,141 | MMBtu | $3.35 |
TOTAL ENERGY COSTS | $1,309,126 | |||
RECOMMENDED SAVINGS* | $194,819 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $181,239 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Primary Product | Electricity Usage | Electricity Demand | LPG | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $12,065 Cost: $11,950 |
- | - | $12,065 | 1,065 | - | - | - | - |
- - kWh |
$12,065 1,065 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,251 Cost: $1,567 |
$716 | 25,498 | $535 | 47 | - | - | - | - |
$716 25,498 kWh |
$535 47 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,515 Cost: - |
$975 | 34,584 | $540 | 48 | - | - | - | - |
$975 34,584 kWh |
$540 48 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $492 Cost: $1,426 |
$264 | 9,379 | $228 | 20 | - | - | - | - |
$264 9,379 kWh |
$228 20 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $19,496 Cost: $24,000 |
- | - | - | - | $19,496 | 6,696 | - | - |
- - kWh |
- - kW-months/year |
$19,496 6,696 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $160,000 Cost: $45,600 |
- | - | - | - | - | - | $160,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$160,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $194,819 Cost: $84,543 |
$1,955 | 69,461 | $13,368 | 1,180 | $19,496 | 6,696 | $160,000 | - | $1,955 69,461 kWh |
$13,368 1,180 kW-months/year |
$19,496 6,696 MMBtu |
$160,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $181,239 Cost: $72,593 |
$980 | 34,877 | $763 | 67 | $19,496 | 6,696 | $160,000 | - | $980 34,877 kWh |
$763 67 kW-months/year |
$19,496 6,696 MMBtu |
$160,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Primary Product | Electricity Usage | Electricity Demand | LPG | Primary Product |