Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Arkansas |
---|---|
Assessment Year | 2000 |
Principal Product | Sawmill Equipment |
NAICS | n/a |
SIC | 3553 - Woodworking Machinery |
Sales | $10,000,000-$50,000,000 |
# of Employees | 175 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 350 Pieces |
Production Hrs. Annual | 2,080 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $45,436 | 1,401,524 | kWh | $0.03 |
Electricity Demand | $42,446 | 2,822 | kW-months/year | $15.04 |
Natural Gas | $19,658 | 3,235 | MMBtu | $6.08 |
TOTAL ENERGY COSTS | $109,301 | |||
RECOMMENDED SAVINGS* | $99,118 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Water Disposal | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,457 Cost: $2,178 |
$809 | 25,205 | $648 | 58 | - | - | - | - | - | - |
$809 25,205 kWh |
$648 58 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7122 DISCONNECT BALLASTS |
Savings: $6,341 Cost: $2,605 |
$3,568 | 108,441 | $2,773 | 250 | - | - | - | - | - | - |
$3,568 108,441 kWh |
$2,773 250 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $26 Cost: - |
$14 | 586 | $12 | 1 | - | - | - | - | - | - |
$14 586 kWh |
$12 1 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $101 Cost: $1,780 |
$56 | 1,758 | $45 | 4 | - | - | - | - | - | - |
$56 1,758 kWh |
$45 4 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,334 Cost: $6,713 |
$981 | 30,774 | $1,353 | 122 | - | - | - | - | - | - |
$981 30,774 kWh |
$1,353 122 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,153 Cost: $120 |
$779 | 24,326 | $374 | 34 | - | - | - | - | - | - |
$779 24,326 kWh |
$374 34 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $7,335 Cost: $500 |
- | - | - | - | $827 | - | $6,508 | - | - | - |
- - kWh |
- - kW-months/year |
$827 - Tgal |
$6,508 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.653 MAINTAIN/ENLARGE A STOCK OF SPARE PARTS |
Savings: $80,371 Cost: $16,150 |
- | - | - | - | - | - | - | - | $80,371 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$80,371 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $99,118 Cost: $30,046 |
$6,207 | 191,090 | $5,205 | 469 | $827 | - | $6,508 | - | $80,371 | - | $6,207 191,090 kWh |
$5,205 469 kW-months/year |
$827 - Tgal |
$6,508 - $ |
$80,371 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||