Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Arkansas
Assessment Year 2000
Principal Product Sawmill Equipment
NAICS n/a
SIC 3553 - Woodworking Machinery
Sales $10,000,000-$50,000,000
# of Employees 175
Plant Area (Sq.Ft.) 150,000
Annual Production 350 Pieces
Production Hrs. Annual 2,080
Location (State) AR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $45,436 1,401,524 kWh $0.03
Electricity Demand $42,446 2,822 kW-months/year $15.04
Natural Gas $19,658 3,235 MMBtu $6.08
TOTAL ENERGY COSTS $109,301
RECOMMENDED SAVINGS* $99,118 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Disposal Ancillary Material Cost Primary Product Electricity Usage Electricity Demand Water Disposal Ancillary Material Cost Primary Product
$ kWh $ kW-months/year $ Tgal $ $ $ $
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,457
Cost:
$2,178
$809 25,205 $648 58 - - - - - - $809
25,205
kWh
$648
58
kW-months/year
-
-
Tgal
-
-
$
-
-
$
02: 2.7122 DISCONNECT BALLASTS Savings:
$6,341
Cost:
$2,605
$3,568 108,441 $2,773 250 - - - - - - $3,568
108,441
kWh
$2,773
250
kW-months/year
-
-
Tgal
-
-
$
-
-
$
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$26
Cost:
-
$14 586 $12 1 - - - - - - $14
586
kWh
$12
1
kW-months/year
-
-
Tgal
-
-
$
-
-
$
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$101
Cost:
$1,780
$56 1,758 $45 4 - - - - - - $56
1,758
kWh
$45
4
kW-months/year
-
-
Tgal
-
-
$
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,334
Cost:
$6,713
$981 30,774 $1,353 122 - - - - - - $981
30,774
kWh
$1,353
122
kW-months/year
-
-
Tgal
-
-
$
-
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,153
Cost:
$120
$779 24,326 $374 34 - - - - - - $779
24,326
kWh
$374
34
kW-months/year
-
-
Tgal
-
-
$
-
-
$
07: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS Savings:
$7,335
Cost:
$500
- - - - $827 - $6,508 - - - -
-
kWh
-
-
kW-months/year
$827
-
Tgal
$6,508
-
$
-
-
$
08: 4.653 MAINTAIN/ENLARGE A STOCK OF SPARE PARTS Savings:
$80,371
Cost:
$16,150
- - - - - - - - $80,371 - -
-
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
$80,371
-
$
TOTAL RECOMMENDED Savings:
$99,118
Cost:
$30,046
$6,207 191,090 $5,205 469 $827 - $6,508 - $80,371 - $6,207
191,090
kWh
$5,205
469
kW-months/year
$827
-
Tgal
$6,508
-
$
$80,371
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ Tgal $ $ $ $
Electricity Usage Electricity Demand Water Disposal Ancillary Material Cost Primary Product Electricity Usage Electricity Demand Water Disposal Ancillary Material Cost Primary Product